Transabdominal Fetal Oximetry via Diffuse Optics: Principled Analysis and Demonstration in Pregnant Ovine Models

Diffuse optics has the potential to offer a substantial advancement in fetal health monitoring via enabling continuous measurement of fetal blood oxygen saturation (fSpO$_2$). Aiming to enhance the sensing accuracy and to elucidate the foundational limits of Transabdominal Fetal Oximetry (TFO) via diffuse optics, we introduce a theoretical derivation, and a comprehensive pipeline for fSpO$_2$ estimation from non-invasively sensed diffuse light intensity values, which are leveraged to analyze datasets obtained through both simulations and in-vivo experiments in gold standard large animal model of pregnancy. We propose the Exponential Pulsation Ratio (EPR) as a key feature, and develop machine-learning models to fuse the information collected across multiple detectors. Our proposed method demonstrates a Mean Absolute Error (MAE) of 4.81% and 6.85% with a Pearson's r correlation of 0.81 (p<0.001) and 0.71 (p<0.001) for estimation of fSpO$_2$ in simulated dataset and in-vivo dataset, respectively. Across both datasets, our method outperforms the existing approaches, enhancing the accuracy of the fSpO$_2$ estimation and demonstrates its viability as a supplemental technology for intrapartum fetal monitoring.

Publication Details

Journal
ArXiv.org
Published
2025-09-25
Primary Topic
Soil Carbon and Nitrogen Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transabdominal Fetal Oximetry via Diffuse Optics: Principled Analysis and Demonstration in Pregnant Ovine Models

ArXiv.org
Soil Carbon and Nitrogen Dynamics
article

Transabdominal Fetal Oximetry via Diffuse Optics: Principled Analysis and Demonstration in Pregnant Ovine Models

article en

Abstract

Diffuse optics has the potential to offer a substantial advancement in fetal health monitoring via enabling continuous measurement of fetal blood oxygen saturation (fSpO$_2$). Aiming to enhance the sensing accuracy and to elucidate the foundational limits of Transabdominal Fetal Oximetry (TFO) via diffuse optics, we introduce a theoretical derivation, and a comprehensive pipeline for fSpO$_2$ estimation from non-invasively sensed diffuse light intensity values, which are leveraged to analyze datasets obtained through both simulations and in-vivo experiments in gold standard large animal model of pregnancy. We propose the Exponential Pulsation Ratio (EPR) as a key feature, and develop machine-learning models to fuse the information collected across multiple detectors. Our proposed method demonstrates a Mean Absolute Error (MAE) of 4.81% and 6.85% with a Pearson's r correlation of 0.81 (p<0.001) and 0.71 (p<0.001) for estimation of fSpO$_2$ in simulated dataset and in-vivo dataset, respectively. Across both datasets, our method outperforms the existing approaches, enhancing the accuracy of the fSpO$_2$ estimation and demonstrates its viability as a supplemental technology for intrapartum fetal monitoring.

ArXiv.org
Openalex Percentile: Top 43%
Soil Carbon and Nitrogen Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.