Organ dose optimization for a point-of-care forearm X-ray photon-counting CT

Background: Spectral shaping is a computed tomography (CT) dose optimization technique that adjusts source voltage and filtration to reduce patient radiation exposure without compromising image quality. Traditionally, radiation dose has been assessed using the computed tomography dose index (CTDI). However, emerging dosimetric approaches aim to enable patient-specific evaluations by estimating organ absorbed doses, providing a more accurate representation of the biological impact. This study investigates spectral shaping for an extremity photon-counting detector (PCD) CT, through organ absorbed dose estimation and image quality evaluation. Method: Monte Carlo simulations were conducted to evaluate various combinations of source voltage and filtration. Tube voltage ranged from 80 to 140 kV, combined with three distinct filtration material and thicknesses. Simulations included three stages: a standardized phantom for CTDI assessment, an adult forearm phantom for organ dose measurement, and an image quality phantom for evaluation of an advanced image quality metric: the detectability index. Results: In a wrist PCD-CT imaging protocol, operating the source at 80 kV can reduce the radiation dose by up to 50%. This reduction is achieved while maintaining the same detectability index value as the standard 120 kV protocol. However, the optimal filtration depends on the organ targeted for dose reduction, as bone and skin benefit from opposing filtration approaches. While CTDI provides a useful initial estimate, it may lead to suboptimal optimization compared to organ-specific dose evaluation. Conclusions: Patient-specific dosimetry based on organ absorbed dose estimation offers a more accurate framework for optimizing CT protocols through spectral shaping than conventional CTDI-based approaches.

Publication Details

Journal
ArXiv.org
Published
2025-09-26
Primary Topic
Fungal Infections and Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Organ dose optimization for a point-of-care forearm X-ray photon-counting CT

ArXiv.org
Fungal Infections and Studies
article

Organ dose optimization for a point-of-care forearm X-ray photon-counting CT

article en

Abstract

Background: Spectral shaping is a computed tomography (CT) dose optimization technique that adjusts source voltage and filtration to reduce patient radiation exposure without compromising image quality. Traditionally, radiation dose has been assessed using the computed tomography dose index (CTDI). However, emerging dosimetric approaches aim to enable patient-specific evaluations by estimating organ absorbed doses, providing a more accurate representation of the biological impact. This study investigates spectral shaping for an extremity photon-counting detector (PCD) CT, through organ absorbed dose estimation and image quality evaluation. Method: Monte Carlo simulations were conducted to evaluate various combinations of source voltage and filtration. Tube voltage ranged from 80 to 140 kV, combined with three distinct filtration material and thicknesses. Simulations included three stages: a standardized phantom for CTDI assessment, an adult forearm phantom for organ dose measurement, and an image quality phantom for evaluation of an advanced image quality metric: the detectability index. Results: In a wrist PCD-CT imaging protocol, operating the source at 80 kV can reduce the radiation dose by up to 50%. This reduction is achieved while maintaining the same detectability index value as the standard 120 kV protocol. However, the optimal filtration depends on the organ targeted for dose reduction, as bone and skin benefit from opposing filtration approaches. While CTDI provides a useful initial estimate, it may lead to suboptimal optimization compared to organ-specific dose evaluation. Conclusions: Patient-specific dosimetry based on organ absorbed dose estimation offers a more accurate framework for optimizing CT protocols through spectral shaping than conventional CTDI-based approaches.

ArXiv.org
Openalex Percentile: Top 39%
Fungal Infections and Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Organ dose optimization for a point-of-care forearm X-ray photon-counting CT · ArXiv.org (2025) | TGRS Research Map | TGRS