Emergence angle and profile at implant-supported crowns with and without cantilever extension: A digital study in molar sites.

Objectives To compare the emergence angle between cantilever and non-cantilever digital designs for implant-supported crowns at molar sites, offering digital analysis insights for evaluating restoration strategy selection.Methods One hundred patients missing the first molar underwent intraoral scanning and CBCT imaging. Data were imported into digital platforms for prosthetic-driven planning and virtual design of implants, abutments and crowns. Two designs (cantilever and non-cantilever) were created for each patient. Emergence angles were measured using both 2D and 3D software. Simple and multiple linear regression models were employed to analyze associations between emergence angles and clinically relevant parameters (crown height and edentulous space).Results The mesiodistal width of first molar edentulous spaces averaged 10.5±0.8mm (range: 9.0-12.5mm). For cantilever restorations, 2D angles measured 23.0±4.5° (mesial) and 22.4±4.6° (distal). Non-cantilever restorations exhibited greater angles, with 2D measurements of 29.1±5.6°(mesial) and 30.4±6.3°(distal) (p < 0.001). When categorizing edentulous spaces into three ranges (9.0-9.9 mm, 10.0-10.9 mm, and 11.0-12.5 mm), mesio-distal emergence angles exceeding 30° occurred in 1.6%, 2.3%, and 10.0% of cantilever designs respectively, compared to 25.8%, 54.6%, and 58.0% in non-cantilever designs (p < 0.001). Cantilever designs consistently produced smaller emergence angles across all edentulous space dimensions.Conclusions Cantilever implant restorations demonstrated smaller emergence angles than non-cantilever designs, suggesting potential advantages for peri-implant health maintenance. These findings provide geometric evidence that may support cantilever designs for first molar replacements when anatomically feasible, though long-term clinical validation remains needed.Clinical Significance The proposed digital emergence angle analysis represents a useful diagnostic method to optimize prosthetic design on use of implant-supported crowns with cantilever extension.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-09-26
DOI
https://doi.org/10.48620/91568
Primary Topic
Islamic Studies and History
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Emergence angle and profile at implant-supported crowns with and without cantilever extension: A digital study in molar sites.

Open Access CRIS of the University of Bern
Islamic Studies and History
article

Emergence angle and profile at implant-supported crowns with and without cantilever extension: A digital study in molar sites.

article en

Abstract

Objectives To compare the emergence angle between cantilever and non-cantilever digital designs for implant-supported crowns at molar sites, offering digital analysis insights for evaluating restoration strategy selection.Methods One hundred patients missing the first molar underwent intraoral scanning and CBCT imaging. Data were imported into digital platforms for prosthetic-driven planning and virtual design of implants, abutments and crowns. Two designs (cantilever and non-cantilever) were created for each patient. Emergence angles were measured using both 2D and 3D software. Simple and multiple linear regression models were employed to analyze associations between emergence angles and clinically relevant parameters (crown height and edentulous space).Results The mesiodistal width of first molar edentulous spaces averaged 10.5±0.8mm (range: 9.0-12.5mm). For cantilever restorations, 2D angles measured 23.0±4.5° (mesial) and 22.4±4.6° (distal). Non-cantilever restorations exhibited greater angles, with 2D measurements of 29.1±5.6°(mesial) and 30.4±6.3°(distal) (p < 0.001). When categorizing edentulous spaces into three ranges (9.0-9.9 mm, 10.0-10.9 mm, and 11.0-12.5 mm), mesio-distal emergence angles exceeding 30° occurred in 1.6%, 2.3%, and 10.0% of cantilever designs respectively, compared to 25.8%, 54.6%, and 58.0% in non-cantilever designs (p < 0.001). Cantilever designs consistently produced smaller emergence angles across all edentulous space dimensions.Conclusions Cantilever implant restorations demonstrated smaller emergence angles than non-cantilever designs, suggesting potential advantages for peri-implant health maintenance. These findings provide geometric evidence that may support cantilever designs for first molar replacements when anatomically feasible, though long-term clinical validation remains needed.Clinical Significance The proposed digital emergence angle analysis represents a useful diagnostic method to optimize prosthetic design on use of implant-supported crowns with cantilever extension.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Sustainable cities and communities
Openalex Percentile: Top 39%
Islamic Studies and History
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.