Development and Validation of Analytical Method for Simultaneous Estimation of Ranitidine and Bismuth Subsalicylate by RP-HPLC

A simple, precise, and accurate Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method was developed and validated for the simultaneous estimation of Ranitidine and Bismuth Subsalicylate in bulk drug substances and pharmaceutical formulations. Chromatographic separation was achieved using a Phenomenex Luna C18 column (4.6 × 150 mm, 5 mm) maintained at a column temperature of 45°C. The mobile phase consisted of Methanol and Water in a ratio of 80:20 v/v, delivered at a flow rate of 1.0 mL/min. Detection was performed at a wavelength of 230 nm, with an injection volume of 10 µL and a total run time of 10 minutes. Both analytes were well resolved with sharp and symmetrical peaks and showed satisfactory retention times. The method was validated according to ICH guidelines, and the results confirmed the method's linearity, precision, accuracy, specificity, and robustness.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-09-30
DOI
https://doi.org/10.5281/zenodo.17233410
Primary Topic
Demographic Trends and Gender Preferences
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of Analytical Method for Simultaneous Estimation of Ranitidine and Bismuth Subsalicylate by RP-HPLC

Zenodo (CERN European Organization for Nuclear Research)
Demographic Trends and Gender Preferences
article

Development and Validation of Analytical Method for Simultaneous Estimation of Ranitidine and Bismuth Subsalicylate by RP-HPLC

article en

Abstract

A simple, precise, and accurate Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method was developed and validated for the simultaneous estimation of Ranitidine and Bismuth Subsalicylate in bulk drug substances and pharmaceutical formulations. Chromatographic separation was achieved using a Phenomenex Luna C18 column (4.6 × 150 mm, 5 mm) maintained at a column temperature of 45°C. The mobile phase consisted of Methanol and Water in a ratio of 80:20 v/v, delivered at a flow rate of 1.0 mL/min. Detection was performed at a wavelength of 230 nm, with an injection volume of 10 µL and a total run time of 10 minutes. Both analytes were well resolved with sharp and symmetrical peaks and showed satisfactory retention times. The method was validated according to ICH guidelines, and the results confirmed the method's linearity, precision, accuracy, specificity, and robustness.

Zenodo (CERN European Organization for Nuclear Research)
Clean water and sanitation
Openalex Percentile: Top 38%
Demographic Trends and Gender Preferences
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.