Artificial Intelligence-Led Whole Coronary Artery OCT Analysis; Validation and Identification of Drug Efficacy and Higher-Risk Plaques.

Background Intracoronary optical coherence tomography (OCT) can identify changes following drug/device treatment and high-risk plaques, but analysis requires expert clinician or core laboratory interpretation, while artifacts and limited sampling markedly impair reproducibility. Assistive technologies such as artificial intelligence-based analysis may therefore aid both detailed OCT interpretation and patient management. We determined if artificial intelligence-based OCT analysis (AutoOCT) can rapidly process, optimize and analyze OCT images, and identify plaque composition changes that predict drug success/failure and high-risk plaques.Methods AutoOCT deep learning artificial intelligence modules were designed to correct segmentation errors from poor-quality or artifact-containing OCT images, identify tissue/plaque composition, classify plaque types, measure multiple parameters including lumen area, lipid and calcium arcs, and fibrous cap thickness, and output segmented images and clinically useful parameters. Model development used 36 212 frames (127 whole pullbacks, 106 patients). Internal validation of tissue and plaque classification and measurements used ex vivo OCT pullbacks from autopsy arteries, while external validation for plaque stabilization and identifying high-risk plaques used core laboratory analysis of IBIS-4 (Integrated Biomarkers and Imaging Study-4) high-intensity statin (83 patients) and CLIMA (Relationship Between Coronary Plaque Morphology of Left Anterior Descending Artery and Long-Term Clinical Outcome Study; 62 patients) studies, respectively.Results AutoOCT recovered images containing common artifacts with measurements and tissue and plaque classification accuracy of 83% versus histology, equivalent to expert clinician readers. AutoOCT replicated core laboratory plaque composition changes after high-intensity statin, including reduced lesion lipid arc (13.3° versus 12.5°) and increased minimum fibrous cap thickness (18.9 µm versus 24.4 µm). AutoOCT also identified high-risk plaque features leading to patient events including minimal lumen area <3.5 mm2, Lipid arc >180°, and fibrous cap thickness <75 µm, similar to the CLIMA core laboratory.Conclusions AutoOCT-based analysis of whole coronary artery OCT identifies tissue and plaque types and measures features correlating with plaque stabilization and high-risk plaques. Artificial intelligence-based OCT analysis may augment clinician or core laboratory analysis of intracoronary OCT images for trials of drug/device efficacy and identifying high-risk lesions.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-09-25
DOI
https://doi.org/10.48620/91569
Primary Topic
Computational Physics and Python Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial Intelligence-Led Whole Coronary Artery OCT Analysis; Validation and Identification of Drug Efficacy and Higher-Risk Plaques.

Open Access CRIS of the University of Bern
Computational Physics and Python Applications
article

Artificial Intelligence-Led Whole Coronary Artery OCT Analysis; Validation and Identification of Drug Efficacy and Higher-Risk Plaques.

article en

Abstract

Background Intracoronary optical coherence tomography (OCT) can identify changes following drug/device treatment and high-risk plaques, but analysis requires expert clinician or core laboratory interpretation, while artifacts and limited sampling markedly impair reproducibility. Assistive technologies such as artificial intelligence-based analysis may therefore aid both detailed OCT interpretation and patient management. We determined if artificial intelligence-based OCT analysis (AutoOCT) can rapidly process, optimize and analyze OCT images, and identify plaque composition changes that predict drug success/failure and high-risk plaques.Methods AutoOCT deep learning artificial intelligence modules were designed to correct segmentation errors from poor-quality or artifact-containing OCT images, identify tissue/plaque composition, classify plaque types, measure multiple parameters including lumen area, lipid and calcium arcs, and fibrous cap thickness, and output segmented images and clinically useful parameters. Model development used 36 212 frames (127 whole pullbacks, 106 patients). Internal validation of tissue and plaque classification and measurements used ex vivo OCT pullbacks from autopsy arteries, while external validation for plaque stabilization and identifying high-risk plaques used core laboratory analysis of IBIS-4 (Integrated Biomarkers and Imaging Study-4) high-intensity statin (83 patients) and CLIMA (Relationship Between Coronary Plaque Morphology of Left Anterior Descending Artery and Long-Term Clinical Outcome Study; 62 patients) studies, respectively.Results AutoOCT recovered images containing common artifacts with measurements and tissue and plaque classification accuracy of 83% versus histology, equivalent to expert clinician readers. AutoOCT replicated core laboratory plaque composition changes after high-intensity statin, including reduced lesion lipid arc (13.3° versus 12.5°) and increased minimum fibrous cap thickness (18.9 µm versus 24.4 µm). AutoOCT also identified high-risk plaque features leading to patient events including minimal lumen area <3.5 mm2, Lipid arc >180°, and fibrous cap thickness <75 µm, similar to the CLIMA core laboratory.Conclusions AutoOCT-based analysis of whole coronary artery OCT identifies tissue and plaque types and measures features correlating with plaque stabilization and high-risk plaques. Artificial intelligence-based OCT analysis may augment clinician or core laboratory analysis of intracoronary OCT images for trials of drug/device efficacy and identifying high-risk lesions.

Open Access CRIS of the University of Bern
No poverty
Openalex Percentile: Top 25%
Computational Physics and Python Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.