Thermal assessment of pole-integrated LiFePO4 energy storage system for arid and non-maintainable locations - A case study in Qatar

<p dir="ltr">Deploying pole-integrated LiFePO<sub>4</sub> storage in hot, low-maintenance urban settings poses a thermal safety challenge. This study assesses the thermal behavior of pole-integrated LiFePO<sub>4</sub> energy storage systems (PIESS) in extreme desert conditions and identifies measures to keep temperatures within safe limits. Field data from 75 PIESS installations across Doha were combined with multiphysics simulations using COMSOL to analyze the internal temperature evolution under varied ambient conditions and charging rates. Six thermal management strategies, including three passive measures (air volume expansion, shading, and heat insulation), two active approaches (forced air convection and thermoelectric Peltier modules), and operational limits that constrain charge/discharge to safe envelopes, are evaluated. The selected methods emphasize low power and scalable solutions, in contrast to liquid or phase change cooling systems commonly reported in the literature, which are often impractical for decentralized applications. The results indicate that at lower charging rates, the battery temperature remains below the critical 60 °C threshold. Active cooling with a 10 W fan limited the temperature rise to 60.8 °C after 1 h at 1C, while multi-module Peltier systems maintained it around 60.6 °C. Passive strategies like air volume expansion and shading provide only modest buffering and are insufficient at high charge rates. The operational limit case demonstrated that maintaining an appropriate charge-to-load ratio effectively restricted the battery temperature within safe boundaries, even under high ambient conditions. These findings provide a thermally validated design approach for enhancing the safety and reliability of battery storage in smart urban infrastructure powered by renewable energy. <h2>Other Information</h2><p dir="ltr">Published in: Journal of Power Sources<br>License: <a href="http://creativecommons.org/licenses/by/4.0/" target="_blank">http://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1016/j.jpowsour.2025.238444" target="_blank">https://dx.doi.org/10.1016/j.jpowsour.2025.238444</a>

Publication Details

Journal
Journal of Power Sources
Published
2025-09-29
DOI
https://doi.org/10.1016/j.jpowsour.2025.238444
Citations
1
Primary Topic
Ectopic Pregnancy Diagnosis and Management
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal assessment of pole-integrated LiFePO4 energy storage system for arid and non-maintainable locations - A case study in Qatar

1 citations
Journal of Power Sources
Ectopic Pregnancy Diagnosis and Management
1.88
article

Thermal assessment of pole-integrated LiFePO4 energy storage system for arid and non-maintainable locations - A case study in Qatar

article en
1 citations

Abstract

<p dir="ltr">Deploying pole-integrated LiFePO<sub>4</sub> storage in hot, low-maintenance urban settings poses a thermal safety challenge. This study assesses the thermal behavior of pole-integrated LiFePO<sub>4</sub> energy storage systems (PIESS) in extreme desert conditions and identifies measures to keep temperatures within safe limits. Field data from 75 PIESS installations across Doha were combined with multiphysics simulations using COMSOL to analyze the internal temperature evolution under varied ambient conditions and charging rates. Six thermal management strategies, including three passive measures (air volume expansion, shading, and heat insulation), two active approaches (forced air convection and thermoelectric Peltier modules), and operational limits that constrain charge/discharge to safe envelopes, are evaluated. The selected methods emphasize low power and scalable solutions, in contrast to liquid or phase change cooling systems commonly reported in the literature, which are often impractical for decentralized applications. The results indicate that at lower charging rates, the battery temperature remains below the critical 60 °C threshold. Active cooling with a 10 W fan limited the temperature rise to 60.8 °C after 1 h at 1C, while multi-module Peltier systems maintained it around 60.6 °C. Passive strategies like air volume expansion and shading provide only modest buffering and are insufficient at high charge rates. The operational limit case demonstrated that maintaining an appropriate charge-to-load ratio effectively restricted the battery temperature within safe boundaries, even under high ambient conditions. These findings provide a thermally validated design approach for enhancing the safety and reliability of battery storage in smart urban infrastructure powered by renewable energy. <h2>Other Information</h2><p dir="ltr">Published in: Journal of Power Sources<br>License: <a href="http://creativecommons.org/licenses/by/4.0/" target="_blank">http://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1016/j.jpowsour.2025.238444" target="_blank">https://dx.doi.org/10.1016/j.jpowsour.2025.238444</a>

Journal of Power SourcesVol. 660
Openalex Percentile: Top 10%
Ectopic Pregnancy Diagnosis and Management
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Thermal assessment of pole-integrated LiFePO4 energy storage system for arid and non-maintainable locations - A case study in Qatar · Journal of Power Sources (2025) | TGRS Research Map | TGRS