Enhancement of the cooling performance of an electrical power transformer using geometrical parameters

This study investigates the influence of electrical transformer shape and fin configuration on the cooling process, emphasizing performance under varying ambient temperatures. Cooling efficiency is critical for transformer reliability, longevity, and operational safety. Traditional transformer shapes often face limitations in heat dissipation, leading to potential hotspots that can affect performance. This research utilized numerical simulations and experimental validation to compare various transformer shapes and fin configurations, focusing particularly on a 250 KVA Oil Natural Air Natural (ONAN) type transformer designed with real-world specifications. Key findings indicated that a hexagonal transformer shape and zigzag-shaped fins with rib configurations spaced at 7 cm intervals provided superior cooling efficiency. This optimized design resulted in a maximum stable temperature of approximately 332.31 K, significantly lower than that observed in traditional rectangular designs. The zigzag fins increased the effective surface area for heat dissipation, facilitating improved thermal performance. Numerical analysis using ANSYS Fluent demonstrated enhanced coolant flow and uniform pressure distribution, with higher coolant velocity reaching 0.252 m/s. This uniformity mitigated potential hotspots and mechanical stress, contributing to overall structural integrity. Experimental validation was conducted under Iraqi weather conditions, reinforcing the numerical results. Temperature tests confirmed that the optimized hexagonal design consistently maintained lower oil and component temperatures than traditional shapes. This study used Finite Element Analysis (FEA) to investigate the impact of changes in geometrical parameters. A theoretical approach based on classical mechanics was applied, where force distribution was modeled using elasticity theory. The percentage difference represents 5.26\% of Coil temperature, 5.1\% of Oil temperature, and 5.25 \% of fins temperature, where the percentage difference represents 1.52\% of all coil temperature, comparing the optimum case with previous research with experimental tests.

Institutions

Publication Details

Journal
Al-Qadisiyah Journal for Engineering Sciences
Published
2025-09-29
DOI
https://doi.org/10.30772/qjes.2024.154157.1408
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancement of the cooling performance of an electrical power transformer using geometrical parameters

Al-Qadisiyah Journal for Engineering Sciences
Power Transformer Diagnostics and Insulation
article

Enhancement of the cooling performance of an electrical power transformer using geometrical parameters

article en

Abstract

This study investigates the influence of electrical transformer shape and fin configuration on the cooling process, emphasizing performance under varying ambient temperatures. Cooling efficiency is critical for transformer reliability, longevity, and operational safety. Traditional transformer shapes often face limitations in heat dissipation, leading to potential hotspots that can affect performance. This research utilized numerical simulations and experimental validation to compare various transformer shapes and fin configurations, focusing particularly on a 250 KVA Oil Natural Air Natural (ONAN) type transformer designed with real-world specifications. Key findings indicated that a hexagonal transformer shape and zigzag-shaped fins with rib configurations spaced at 7 cm intervals provided superior cooling efficiency. This optimized design resulted in a maximum stable temperature of approximately 332.31 K, significantly lower than that observed in traditional rectangular designs. The zigzag fins increased the effective surface area for heat dissipation, facilitating improved thermal performance. Numerical analysis using ANSYS Fluent demonstrated enhanced coolant flow and uniform pressure distribution, with higher coolant velocity reaching 0.252 m/s. This uniformity mitigated potential hotspots and mechanical stress, contributing to overall structural integrity. Experimental validation was conducted under Iraqi weather conditions, reinforcing the numerical results. Temperature tests confirmed that the optimized hexagonal design consistently maintained lower oil and component temperatures than traditional shapes. This study used Finite Element Analysis (FEA) to investigate the impact of changes in geometrical parameters. A theoretical approach based on classical mechanics was applied, where force distribution was modeled using elasticity theory. The percentage difference represents 5.26\% of Coil temperature, 5.1\% of Oil temperature, and 5.25 \% of fins temperature, where the percentage difference represents 1.52\% of all coil temperature, comparing the optimum case with previous research with experimental tests.

Al-Qadisiyah Journal for Engineering SciencesVol. 18(3)
University of Wasit (IQ)
Affordable and clean energy
Openalex Percentile: Top 50%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancement of the cooling performance of an electrical power transformer using geometrical parameters · Al-Qadisiyah Journal for Engineering Sciences (2025) | TGRS Research Map | TGRS