Thin-plate stress monitoring using S1-ZGV mode based on a PVDF comb transducer

This Letter proposes an ultrasonic stress monitoring method utilizing the S1 zero group velocity (S1-ZGV) mode based on a PVDF comb transducer. Experimental investigations have revealed that under varying uniaxial stress conditions, both the measured S1-ZGV frequency and its corresponding amplitude exhibit appreciable variations. By adopting the relative change rate of the amplitude corresponding to the S1-ZGV frequency (denoted by RCA) as the characteristic parameter, it is evident that RCA demonstrates a monotonic and highly sensitive response to the applied uniaxial stress. Notably, RCA exhibits a significant increase as the applied uniaxial stress rises. This characteristic enables the use of RCA to predict the stress state, facilitating real-time stress monitoring. Experimental validation indicates that the predicted stress values align closely with the actual applied stress values, demonstrating a high level of accuracy in stress prediction. This method enables real-time and in situ monitoring of the stress state in thin plates subjected to uniaxial stresses, which holds paramount importance for a wide array of industrial applications in structural health monitoring.

Institutions

Publication Details

Journal
Applied Physics Letters
Published
2025-09-29
DOI
https://doi.org/10.1063/5.0297746
Citations
2
Primary Topic
Library Science and Administration
Type
article
Field-Weighted Citation Impact
23.06
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thin-plate stress monitoring using S1-ZGV mode based on a PVDF comb transducer

2 citations
Applied Physics Letters
Library Science and Administration
23.06
article

Thin-plate stress monitoring using S1-ZGV mode based on a PVDF comb transducer

article en
2 citations

Abstract

This Letter proposes an ultrasonic stress monitoring method utilizing the S1 zero group velocity (S1-ZGV) mode based on a PVDF comb transducer. Experimental investigations have revealed that under varying uniaxial stress conditions, both the measured S1-ZGV frequency and its corresponding amplitude exhibit appreciable variations. By adopting the relative change rate of the amplitude corresponding to the S1-ZGV frequency (denoted by RCA) as the characteristic parameter, it is evident that RCA demonstrates a monotonic and highly sensitive response to the applied uniaxial stress. Notably, RCA exhibits a significant increase as the applied uniaxial stress rises. This characteristic enables the use of RCA to predict the stress state, facilitating real-time stress monitoring. Experimental validation indicates that the predicted stress values align closely with the actual applied stress values, demonstrating a high level of accuracy in stress prediction. This method enables real-time and in situ monitoring of the stress state in thin plates subjected to uniaxial stresses, which holds paramount importance for a wide array of industrial applications in structural health monitoring.

Applied Physics LettersVol. 127(13)
Chongqing University (CN), Xiamen University (CN), Xiamen University of Technology (CN)
Openalex Percentile: Top 1%
Library Science and Administration
23.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.