Microscope for investigating the size of an EUV radiation source emitting at 11.2 nm

Abstract In this article, we report on the development, construction and operation of a microscope to study the emission radiation of laser plasma in the EUV spectral range. The main optical unit of the microscope is a two-mirror spherical Schwarzschild objective with a 5x magnification. The microscope builds an image of the plasma cloud at a wavelength of 11.25 nm. This wavelength is determined by the manufactured multilayer x-ray mirrors based on a Mo/Be structure. To suppress the long-wave noise component of the signal in the VUV, UV, visible and IR spectral range, we used two thin-film Mo/Be filters. The device was calibrated on the basis of both EUV radiation registration efficiency and spatial resolution at the operating wavelength, these being 12% and 3.9 μm, respectively. We also discuss the results of studying the size of a laser spark in gas-jet targets.

Publication Details

Journal
Measurement Science and Technology
Published
2025-09-29
DOI
https://doi.org/10.1088/1361-6501/ae0cec
Citations
1
Primary Topic
Pharmacological Effects and Toxicity Studies
Type
article
Field-Weighted Citation Impact
3.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microscope for investigating the size of an EUV radiation source emitting at 11.2 nm

1 citations
Measurement Science and Technology
Pharmacological Effects and Toxicity Studies
3.49
article

Microscope for investigating the size of an EUV radiation source emitting at 11.2 nm

article en
1 citations

Abstract

Abstract In this article, we report on the development, construction and operation of a microscope to study the emission radiation of laser plasma in the EUV spectral range. The main optical unit of the microscope is a two-mirror spherical Schwarzschild objective with a 5x magnification. The microscope builds an image of the plasma cloud at a wavelength of 11.25 nm. This wavelength is determined by the manufactured multilayer x-ray mirrors based on a Mo/Be structure. To suppress the long-wave noise component of the signal in the VUV, UV, visible and IR spectral range, we used two thin-film Mo/Be filters. The device was calibrated on the basis of both EUV radiation registration efficiency and spatial resolution at the operating wavelength, these being 12% and 3.9 μm, respectively. We also discuss the results of studying the size of a laser spark in gas-jet targets.

Measurement Science and TechnologyVol. 36(10)
Affordable and clean energy
Openalex Percentile: Top 6%
Pharmacological Effects and Toxicity Studies
3.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.