EFFECT OF WATER FLOW RATE AND AIR VELOCITY ON THE PERFORMANCE OF EVAPORATIVE COOLING SYSTEM FOR GREENHOUSE

Climate change has become one of the most critical challenges affecting agricultural production worldwide. Environmental control inside greenhouses provides an effective strategy to mitigate the adverse impacts of such climatic variations. The primary objective of this study was to optimize the operational parameters of an evaporative cooling system, namely water flow rate and air velocity. To achieve this, experiments were conducted under three different water flow rates (2, 4, and 6 L·min⁻¹·m⁻²) and three air velocities (1.0, 1.25, and 1.5 m·s⁻¹), with and without shading nets. The effects of these parameters on greenhouse air temperature, relative humidity, cooling efficiency, and cooling capacity were evaluated. The findings revealed a clear correlation between indoor and outdoor air temperatures, where the indoor temperature followed the outdoor trend, increasing during the early morning, peaking at noon, and then declining as solar radiation decreased. Similarly, the relative humidity of the outdoor air increased during nighttime and decreased during daytime in response to the temperature rise. The results demonstrated that the maximum cooling efficiency (94.36%) was achieved at an air velocity of 1.25 m·s⁻¹ and a water flow rate of 4 L·min⁻¹·m⁻² in the presence of shading nets. In contrast, the highest cooling capacity (91.96 kW) was obtained at an air velocity of 1.5 m·s⁻¹ with the same water flow rate under shaded conditions. In general, the most efficient performance is achieved by operating the evaporative cooling system with shading nets at a water flow rate of 4 L·min⁻¹·m⁻² and an air velocity of 1.25 m·s⁻¹. This combination not only maximizes cooling efficiency but also contributes to achieving a more stable greenhouse microclimate.

Institutions

Publication Details

Journal
Menoufia Journal of Agricultural Engineering
Published
2025-08-30
DOI
https://doi.org/10.21608/maje.2025.415542.1015
Primary Topic
Wireless Sensor Networks for Data Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EFFECT OF WATER FLOW RATE AND AIR VELOCITY ON THE PERFORMANCE OF EVAPORATIVE COOLING SYSTEM FOR GREENHOUSE

Menoufia Journal of Agricultural Engineering
Wireless Sensor Networks for Data Analysis
article

EFFECT OF WATER FLOW RATE AND AIR VELOCITY ON THE PERFORMANCE OF EVAPORATIVE COOLING SYSTEM FOR GREENHOUSE

article en

Abstract

Climate change has become one of the most critical challenges affecting agricultural production worldwide. Environmental control inside greenhouses provides an effective strategy to mitigate the adverse impacts of such climatic variations. The primary objective of this study was to optimize the operational parameters of an evaporative cooling system, namely water flow rate and air velocity. To achieve this, experiments were conducted under three different water flow rates (2, 4, and 6 L·min⁻¹·m⁻²) and three air velocities (1.0, 1.25, and 1.5 m·s⁻¹), with and without shading nets. The effects of these parameters on greenhouse air temperature, relative humidity, cooling efficiency, and cooling capacity were evaluated. The findings revealed a clear correlation between indoor and outdoor air temperatures, where the indoor temperature followed the outdoor trend, increasing during the early morning, peaking at noon, and then declining as solar radiation decreased. Similarly, the relative humidity of the outdoor air increased during nighttime and decreased during daytime in response to the temperature rise. The results demonstrated that the maximum cooling efficiency (94.36%) was achieved at an air velocity of 1.25 m·s⁻¹ and a water flow rate of 4 L·min⁻¹·m⁻² in the presence of shading nets. In contrast, the highest cooling capacity (91.96 kW) was obtained at an air velocity of 1.5 m·s⁻¹ with the same water flow rate under shaded conditions. In general, the most efficient performance is achieved by operating the evaporative cooling system with shading nets at a water flow rate of 4 L·min⁻¹·m⁻² and an air velocity of 1.25 m·s⁻¹. This combination not only maximizes cooling efficiency but also contributes to achieving a more stable greenhouse microclimate.

Menoufia Journal of Agricultural EngineeringVol. 8(6)
Menoufia University (EG)
Clean water and sanitation
Openalex Percentile: Top 44%
Wireless Sensor Networks for Data Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.