METHOD DEVELOPMENT AND VALIDATION OF ALECTINIB DRUG BY RP HPLC BULK AND PHARMACEUTICAL DOSAGE FROM

A novel, simple, precise, and accurate Reverse-Phase High-Performance Liquid Chromatographic (RP-HPLC) method was developed and validated for the estimation of Alectinib in bulk and pharmaceutical dosage forms. The chromatographic separation was achieved on a Zorbax Eclipse XDB-C18 column (150 × 4.6 mm, 5 µm) using an isocratic mobile phase consisting of Acetonitrile and Water (50:50 v/v), adjusted to pH 3.0 with orthophosphoric acid. The flow rate was 0.8 mL/min, and detection was carried out using a PDA detector at 265 nm. The retention time for Alectinib was found to be 3.3 minutes. The method was validated as per ICH Q2(R1) guidelines. The calibration curve was linear over the concentration range of 10-50 µg/mL (r² = 0.9989). The method demonstrated excellent precision (%RSD < 1) and accuracy (recovery between 98.5% and 100.6%).The limits of detection (LOD) and quantitation (LOQ) were 0.18 µg/mL and 0.57 µg/mL, respectively. The proposed method was successfully applied for the assay of a marketed tablet formulation (Alecensa®), yielding a result of 99.2% of the label claim. This method is rapid, reliable, and suitable for routine quality control analysis of Alectinib.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-01
DOI
https://doi.org/10.5281/zenodo.17214067
Primary Topic
Agriculture, Water, and Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

METHOD DEVELOPMENT AND VALIDATION OF ALECTINIB DRUG BY RP HPLC BULK AND PHARMACEUTICAL DOSAGE FROM

Zenodo (CERN European Organization for Nuclear Research)
Agriculture, Water, and Health
article

METHOD DEVELOPMENT AND VALIDATION OF ALECTINIB DRUG BY RP HPLC BULK AND PHARMACEUTICAL DOSAGE FROM

article en

Abstract

A novel, simple, precise, and accurate Reverse-Phase High-Performance Liquid Chromatographic (RP-HPLC) method was developed and validated for the estimation of Alectinib in bulk and pharmaceutical dosage forms. The chromatographic separation was achieved on a Zorbax Eclipse XDB-C18 column (150 × 4.6 mm, 5 µm) using an isocratic mobile phase consisting of Acetonitrile and Water (50:50 v/v), adjusted to pH 3.0 with orthophosphoric acid. The flow rate was 0.8 mL/min, and detection was carried out using a PDA detector at 265 nm. The retention time for Alectinib was found to be 3.3 minutes. The method was validated as per ICH Q2(R1) guidelines. The calibration curve was linear over the concentration range of 10-50 µg/mL (r² = 0.9989). The method demonstrated excellent precision (%RSD < 1) and accuracy (recovery between 98.5% and 100.6%).The limits of detection (LOD) and quantitation (LOQ) were 0.18 µg/mL and 0.57 µg/mL, respectively. The proposed method was successfully applied for the assay of a marketed tablet formulation (Alecensa®), yielding a result of 99.2% of the label claim. This method is rapid, reliable, and suitable for routine quality control analysis of Alectinib.

Zenodo (CERN European Organization for Nuclear Research)
Clean water and sanitation
Openalex Percentile: Top 51%
Agriculture, Water, and Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.