Demonstration-scale urban wastewater reclamation using concentrated solar radiation

This study explores the potential of solar disinfection (SODIS) enhanced by solar concentration technology for urban wastewater reclamation at demonstration scale, with application to crop irrigation, highlighting a novel approach to integrating renewable energy into wastewater treatment while reducing operational costs and environmental impact. A pioneering demonstration plant, based on a 36-m 2 Fresnel solar collector, was set up at an urban wastewater treatment plant (WWTP) in Almería (Spain) to evaluate the inactivation of Escherichia coli ( E. coli ) and total coliforms under continuous-flow operation. Preliminary laboratory experiments were conducted to study E. coli inactivation at different operating temperatures and UV-A irradiances using actual secondary effluent. The demonstration plant was designed, constructed, and automated following these results. Its operation was assessed at outlet temperatures of 40, 50, 60, and 70 °C for two configurations: one involving a preheating/aftercooling stage based on heat recovery through a tube-and-shell heat exchanger, and the other without it. Log reduction values (LRVs) of 2.0 ± 0.1 and 5.6 ± 0.1 in E. coli concentration were achieved using the enhanced system configuration (Fresnel + heat exchanger) at 50 °C (200 L h −1 ) and 60 °C (150 L h −1 ), respectively. Furthermore, the addition of 20 ppm of H₂O₂ as a chemical enhancement for disinfection (solar/H 2 O 2 ) was studied at an outlet temperature of 50 °C, resulting in LRV increases of up to 1.6 in E. coli concentration. • A 36-m 2 Fresnel solar collector was evaluated for urban wastewater reclamation. • Classical cascade control strategy was implemented for the outlet temperature. • The plant baseline design was upgraded by implementing an energy recovery stage. • Reclaimed water qualities Class D (200 L h −1 ) and Class A (150 L h −1 ) were achieved. • H 2 O 2 dosing was proposed as a complementary strategy for low-radiation intervals.

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2025-09-27
DOI
https://doi.org/10.1016/j.jwpe.2025.108817
Primary Topic
Wastewater Treatment and Reuse
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Demonstration-scale urban wastewater reclamation using concentrated solar radiation

Journal of Water Process Engineering
Wastewater Treatment and Reuse
article

Demonstration-scale urban wastewater reclamation using concentrated solar radiation

article en

Abstract

This study explores the potential of solar disinfection (SODIS) enhanced by solar concentration technology for urban wastewater reclamation at demonstration scale, with application to crop irrigation, highlighting a novel approach to integrating renewable energy into wastewater treatment while reducing operational costs and environmental impact. A pioneering demonstration plant, based on a 36-m 2 Fresnel solar collector, was set up at an urban wastewater treatment plant (WWTP) in Almería (Spain) to evaluate the inactivation of Escherichia coli ( E. coli ) and total coliforms under continuous-flow operation. Preliminary laboratory experiments were conducted to study E. coli inactivation at different operating temperatures and UV-A irradiances using actual secondary effluent. The demonstration plant was designed, constructed, and automated following these results. Its operation was assessed at outlet temperatures of 40, 50, 60, and 70 °C for two configurations: one involving a preheating/aftercooling stage based on heat recovery through a tube-and-shell heat exchanger, and the other without it. Log reduction values (LRVs) of 2.0 ± 0.1 and 5.6 ± 0.1 in E. coli concentration were achieved using the enhanced system configuration (Fresnel + heat exchanger) at 50 °C (200 L h −1 ) and 60 °C (150 L h −1 ), respectively. Furthermore, the addition of 20 ppm of H₂O₂ as a chemical enhancement for disinfection (solar/H 2 O 2 ) was studied at an outlet temperature of 50 °C, resulting in LRV increases of up to 1.6 in E. coli concentration. • A 36-m 2 Fresnel solar collector was evaluated for urban wastewater reclamation. • Classical cascade control strategy was implemented for the outlet temperature. • The plant baseline design was upgraded by implementing an energy recovery stage. • Reclaimed water qualities Class D (200 L h −1 ) and Class A (150 L h −1 ) were achieved. • H 2 O 2 dosing was proposed as a complementary strategy for low-radiation intervals.

Journal of Water Process EngineeringVol. 78
Hospital Virgen del Camino (ES), University of Almería (ES)
Clean water and sanitation
Openalex Percentile: Top 46%
Wastewater Treatment and Reuse
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.