Mitigating Mesh-Induced Errors in Time-Domain Simulation of Medical Microwave Imaging

With the rapid development of medical microwave imaging systems, their accurate simulation becomes important to ensure the reliability of the developed hardware and software before moving to clinical tests. This is particularly important when using machine learning techniques that require a large volume of simulated data for training. Since the target responses in medical microwave imaging are quite weak, the numerical errors and variations caused by different meshing used in numerical simulations most likely mask the target response; thus, interfering with the pattern of the simulated dataset and resulting in misleading results. Since most available bio-models are voxel-based and can only be meshed using hexahedra, this article focuses on time-domain solvers that use hexahedral meshing. It investigates numerical modeling errors caused by mesh variations in realistic three-dimensional (3D) simulations, their impact on data distribution for machine learning algorithms, and the trade-off between convergence and total simulation time. A realistic 3D microwave head imaging system is used as an example. A delta-simulation approach is presented to eliminate data variations in the constructed dataset caused by inconsistent mesh distributions across simulated cases. The kernel principal component analysis and k-means clustering techniques are used to evaluate the proposed approach. The assessments show that the proposed delta-simulation method can generate a dataset with a more informative data distribution, thereby facilitating subsequent machine learning algorithms. In addition, the delta-simulation balances accuracy and efficiency by maintaining an acceptable number of mesh elements that can be simulated in a reasonable time.

Institutions

Publication Details

Journal
IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology
Published
2025-09-26
DOI
https://doi.org/10.1109/jerm.2025.3611942
Primary Topic
Image Processing and 3D Reconstruction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigating Mesh-Induced Errors in Time-Domain Simulation of Medical Microwave Imaging

IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology
Image Processing and 3D Reconstruction
article

Mitigating Mesh-Induced Errors in Time-Domain Simulation of Medical Microwave Imaging

article en

Abstract

With the rapid development of medical microwave imaging systems, their accurate simulation becomes important to ensure the reliability of the developed hardware and software before moving to clinical tests. This is particularly important when using machine learning techniques that require a large volume of simulated data for training. Since the target responses in medical microwave imaging are quite weak, the numerical errors and variations caused by different meshing used in numerical simulations most likely mask the target response; thus, interfering with the pattern of the simulated dataset and resulting in misleading results. Since most available bio-models are voxel-based and can only be meshed using hexahedra, this article focuses on time-domain solvers that use hexahedral meshing. It investigates numerical modeling errors caused by mesh variations in realistic three-dimensional (3D) simulations, their impact on data distribution for machine learning algorithms, and the trade-off between convergence and total simulation time. A realistic 3D microwave head imaging system is used as an example. A delta-simulation approach is presented to eliminate data variations in the constructed dataset caused by inconsistent mesh distributions across simulated cases. The kernel principal component analysis and k-means clustering techniques are used to evaluate the proposed approach. The assessments show that the proposed delta-simulation method can generate a dataset with a more informative data distribution, thereby facilitating subsequent machine learning algorithms. In addition, the delta-simulation balances accuracy and efficiency by maintaining an acceptable number of mesh elements that can be simulated in a reasonable time.

IEEE Journal of Electromagnetics RF and Microwaves in Medicine and BiologyVol. 10(1)
The University of Queensland (AU), The University of Adelaide (AU)
Openalex Percentile: Top 46%
Image Processing and 3D Reconstruction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mitigating Mesh-Induced Errors in Time-Domain Simulation of Medical Microwave Imaging · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology (2025) | TGRS Research Map | TGRS