Validation and Development of a Robust RP-HPLC Method for Simultaneous Estimation of Ciprofloxacin and Ornidazole in Pharmaceutical Formulations

A rapid, precise, and robust reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous estimation of Ciprofloxacin and Ornidazole in pharmaceutical dosage forms. The method was optimized using a C18 column (250mm × 4.6mm, 5µm), with a mobile phase consisting of methanol and phosphate buffer (pH 3.5) in a ratio of 60:40 v/v, at a flow rate of 1.0mL/min. Detection was performed at 294nm. The method was validated per ICH guidelines, assessing parameters including specificity, linearity, accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), and robustness. The results demonstrated that the method is suitable for routine quality control of Ciprofloxacin and Ornidazole in pharmaceutical preparations.

Institutions

Publication Details

Journal
Research Journal of Pharmacy and Technology
Published
2025-08-02
DOI
https://doi.org/10.52711/0974-360x.2025.00507
Citations
1
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
2.48
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation and Development of a Robust RP-HPLC Method for Simultaneous Estimation of Ciprofloxacin and Ornidazole in Pharmaceutical Formulations

1 citations
Research Journal of Pharmacy and Technology
Geochemistry and Geologic Mapping
2.48
article

Validation and Development of a Robust RP-HPLC Method for Simultaneous Estimation of Ciprofloxacin and Ornidazole in Pharmaceutical Formulations

article en
1 citations

Abstract

A rapid, precise, and robust reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous estimation of Ciprofloxacin and Ornidazole in pharmaceutical dosage forms. The method was optimized using a C18 column (250mm × 4.6mm, 5µm), with a mobile phase consisting of methanol and phosphate buffer (pH 3.5) in a ratio of 60:40 v/v, at a flow rate of 1.0mL/min. Detection was performed at 294nm. The method was validated per ICH guidelines, assessing parameters including specificity, linearity, accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), and robustness. The results demonstrated that the method is suitable for routine quality control of Ciprofloxacin and Ornidazole in pharmaceutical preparations.

Research Journal of Pharmacy and Technology
Nagpur Institute of Technology (IN)
Openalex Percentile: Top 7%
Geochemistry and Geologic Mapping
2.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.