A Novel Configuration of a 20 MW LTS Wind Generator With a Cryogenic Pipe Cooling System

Superconducting generators offer a promising solution for far-offshore wind power that has a capacity of 20 MW and above. This paper proposes a novel configuration for high-power low-temperature superconducting (LTS) wind generators with a thermosiphon helium pipe cooling system on the superconducting excitation rotor. Three groups of cold heads, each with a condenser, are symmetrically arranged circumferentially around the excitation rotor, which has been preliminarily validated to enable natural circulation of helium along the helium cooling pipes without any pump no matter the rotor rotates or keeps standstill at any angle. A conceptual design for a 20 MW LTS wind generator incorporating the novel configuration has been developed, covering electromagnetic, structural, and cryogenic aspects. The design features 72 LTS excitation coils, achieving a radial air-gap flux density of 2.5 T with rated armature voltage and current of 3300 V and 3500 A, respectively. The generator has an air-gap diameter of 7.2 m, an axial length of 1.6 m and an active weight of roughly 130 tons. Preliminary analysis of electromagnetic, structural, and cryogenic performances of the generator has been conducted by 2D finite element simulations and analytical calculations. The maximum magnetic field on the superconducting coils is 6.6 T, and the maximum stresses on the superconducting coils and the torque tubes are 37 MPa and 137 MPa, respectively. The total heat leakages from 300 K to 50 K and from 50 K to 4.2 K within the cryostat are 174.8 W and 4.65 W respectively, sufficiently covered by the combined cooling capacity of nine cold heads in the system, each providing 70 W at 50 K and 1.25 W at 4.2 K. The highest temperature on the superconducting coils is 4.3 K.

Institutions

Publication Details

Journal
IEEE Transactions on Applied Superconductivity
Published
2025-09-26
DOI
https://doi.org/10.1109/tasc.2025.3614567
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Configuration of a 20 MW LTS Wind Generator With a Cryogenic Pipe Cooling System

IEEE Transactions on Applied Superconductivity
Geochemistry and Geologic Mapping
article

A Novel Configuration of a 20 MW LTS Wind Generator With a Cryogenic Pipe Cooling System

article en

Abstract

Superconducting generators offer a promising solution for far-offshore wind power that has a capacity of 20 MW and above. This paper proposes a novel configuration for high-power low-temperature superconducting (LTS) wind generators with a thermosiphon helium pipe cooling system on the superconducting excitation rotor. Three groups of cold heads, each with a condenser, are symmetrically arranged circumferentially around the excitation rotor, which has been preliminarily validated to enable natural circulation of helium along the helium cooling pipes without any pump no matter the rotor rotates or keeps standstill at any angle. A conceptual design for a 20 MW LTS wind generator incorporating the novel configuration has been developed, covering electromagnetic, structural, and cryogenic aspects. The design features 72 LTS excitation coils, achieving a radial air-gap flux density of 2.5 T with rated armature voltage and current of 3300 V and 3500 A, respectively. The generator has an air-gap diameter of 7.2 m, an axial length of 1.6 m and an active weight of roughly 130 tons. Preliminary analysis of electromagnetic, structural, and cryogenic performances of the generator has been conducted by 2D finite element simulations and analytical calculations. The maximum magnetic field on the superconducting coils is 6.6 T, and the maximum stresses on the superconducting coils and the torque tubes are 37 MPa and 137 MPa, respectively. The total heat leakages from 300 K to 50 K and from 50 K to 4.2 K within the cryostat are 174.8 W and 4.65 W respectively, sufficiently covered by the combined cooling capacity of nine cold heads in the system, each providing 70 W at 50 K and 1.25 W at 4.2 K. The highest temperature on the superconducting coils is 4.3 K.

IEEE Transactions on Applied SuperconductivityVol. 36(3)
Midea Group (China) (CN), Tsinghua University (CN)
Affordable and clean energy
Openalex Percentile: Top 27%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel Configuration of a 20 MW LTS Wind Generator With a Cryogenic Pipe Cooling System · IEEE Transactions on Applied Superconductivity (2025) | TGRS Research Map | TGRS