Background: T2-mapping has promise to evaluate kidney pathophysiology. Prior studies show a large variance in kidney T2, likely due to the differing acquisition sequences. Purpose: To compare four T2-mapping sequences to investigate kidney T2.Study Type: Phantom and prospective in-vivo assessments.Participants: ISMRM/NIST and QASPER phantoms;8 healthy volunteers (4 female,30±8 years).Field Strength/Sequence: 3T. Spin echo-echo planar imaging (SE-EPI), multi-echo-spin echo (ME-SE), Gradient and Spin Echo (GraSE) vendor-provided sequences, and custom T2-prepared EPI, Dual-echo B0-mapping and DREAM B1-mapping.Assessment: T2-mapping accuracy in the ISMRM/NIST phantom in the presence of B0 frequency offset and B1+ by scaling of flip angles, and in the QASPER phantom in presence of diffusion by altering pump rate compared to being turned off. Participants underwent a single 45-min exam to collect four T2-mapping sequences, B0 and B1 maps. In-vivo T2 values compared across sequences and influence of B0 and B1+ was evaluated.Statistical Tests: Shapiro-Wilk, Wilcoxon signed-rank, Student’s t-test, Coefficient of Variation, Pearson’s correlation coefficient, linear mixed effect model. p<0.05 considered statistically significant.Results: SE-EPI, ME-SE, GraSE, and T2-prepared EPI had a mean absolute scaled error of 0.52, 0.52, 0.36, and 0.27 over kidney T2 range of the ISMRM/NIST phantom. GraSE was most robust to perturbations in B0/B1+. In the QASPER phantom, SE-EPI was highly sensitive to diffusion leading to T2 shortening (66%), whilst multi-echo sequences had lower diffusion sensitivity ordered by shortest echo spacing (ME-SE 81%, T2-prepared EPI 90%, GraSE 95% reduction in T2). In-vivo, SE-EPI measured T2 was significantly lower than multi-echo sequences, and SE-EPI and T2-preparation had a -0.52±0.08ms/% and -0.57±0.06ms/% dependence on B1+. Data Conclusion: To reduce B0, B1+ and diffusion sensitivity for kidney T2-mapping, a multi-echo sequence spanning echo times up to the kidney T2 (~140ms at 3T) is recommended. Collecting data with different echo-spacings can isolate the diffusion- related T2 component.

Publication Details

Journal
Repository@Nottingham (University of Nottingham)
Published
2025-09-12
Primary Topic
Research on scale insects
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the Impact of Imaging Parameters on MRI Measurement of Kidney T2

Repository@Nottingham (University of Nottingham)
Research on scale insects
article

Assessing the Impact of Imaging Parameters on MRI Measurement of Kidney T2

article en

Abstract

Background: T2-mapping has promise to evaluate kidney pathophysiology. Prior studies show a large variance in kidney T2, likely due to the differing acquisition sequences. Purpose: To compare four T2-mapping sequences to investigate kidney T2.Study Type: Phantom and prospective in-vivo assessments.Participants: ISMRM/NIST and QASPER phantoms;8 healthy volunteers (4 female,30±8 years).Field Strength/Sequence: 3T. Spin echo-echo planar imaging (SE-EPI), multi-echo-spin echo (ME-SE), Gradient and Spin Echo (GraSE) vendor-provided sequences, and custom T2-prepared EPI, Dual-echo B0-mapping and DREAM B1-mapping.Assessment: T2-mapping accuracy in the ISMRM/NIST phantom in the presence of B0 frequency offset and B1+ by scaling of flip angles, and in the QASPER phantom in presence of diffusion by altering pump rate compared to being turned off. Participants underwent a single 45-min exam to collect four T2-mapping sequences, B0 and B1 maps. In-vivo T2 values compared across sequences and influence of B0 and B1+ was evaluated.Statistical Tests: Shapiro-Wilk, Wilcoxon signed-rank, Student’s t-test, Coefficient of Variation, Pearson’s correlation coefficient, linear mixed effect model. p<0.05 considered statistically significant.Results: SE-EPI, ME-SE, GraSE, and T2-prepared EPI had a mean absolute scaled error of 0.52, 0.52, 0.36, and 0.27 over kidney T2 range of the ISMRM/NIST phantom. GraSE was most robust to perturbations in B0/B1+. In the QASPER phantom, SE-EPI was highly sensitive to diffusion leading to T2 shortening (66%), whilst multi-echo sequences had lower diffusion sensitivity ordered by shortest echo spacing (ME-SE 81%, T2-prepared EPI 90%, GraSE 95% reduction in T2). In-vivo, SE-EPI measured T2 was significantly lower than multi-echo sequences, and SE-EPI and T2-preparation had a -0.52±0.08ms/% and -0.57±0.06ms/% dependence on B1+. Data Conclusion: To reduce B0, B1+ and diffusion sensitivity for kidney T2-mapping, a multi-echo sequence spanning echo times up to the kidney T2 (~140ms at 3T) is recommended. Collecting data with different echo-spacings can isolate the diffusion- related T2 component.

Repository@Nottingham (University of Nottingham)
Openalex Percentile: Top 42%
Research on scale insects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessing the Impact of Imaging Parameters on MRI Measurement of Kidney T2 · Repository@Nottingham (University of Nottingham) (2025) | TGRS Research Map | TGRS