Development of an acoustic dose-profile measurement technique for short pulse proton and ion beams

Cancer is the second leading cause of death globally, with radiotherapy treating about 50\% of patients. Conventional radiotherapy uses photons, however, it often irradiates healthy cells surrounding the cancerous region. New treatment facilities are turning to protons and light ions, which deposit a maximum dose within a small volume at the end of their range. This thesis introduces LhARA, the Laser-hybrid Accelerator for Radiobiological Applications, which aims to advance radiobiology by exploring how different particle beam characteristics affect therapeutic outcomes. Using pulsed proton and light-ion beams, LhARA offers flexibility in ion species, beam widths, and pulse duration. To minimize uncertainties, real-time dose delivery monitoring is essential. This work presents the SmartPhantom, a novel detector for monitoring three-dimensional dose accumulation delivered using nanosecond-scale ion beam pulses. Unlike existing devices that provide only relative dose values, the SmartPhantom delivers calibrated feedback. The detector uses ultrasound waves induced by the transient pressure increase as the beam propagates through matter. Due to the high speed of ultrasound, feedback is nearly instantaneous. To calibrate the acoustic response, a liquid scintillator is used as the propagating medium inside the detector. The scintillation light emitted during beam propagation, combined with known photon yields, enables absolute dose reconstruction. The SmartPhantom was evaluated at the MC40 cyclotron in Birmingham and the LION accelerator at CALA in Munich. To optimize the design, a simulation pipeline was developed using Python for source parametrization, BDSIM for particle tracking, Geant4 for energy deposition calculations, and Matlab for acoustic modeling. The results revealed strong correlation between optical and acoustic measurements, validating the detector's potential. This lays the foundation for a clinically viable, real-time dose monitoring system.

Institutions

Publication Details

Journal
Imperial College Research Computing Service Data Repository
Published
2025-04-08
DOI
https://doi.org/10.25560/121726
Primary Topic
Religion and Society Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an acoustic dose-profile measurement technique for short pulse proton and ion beams

Imperial College Research Computing Service Data Repository
Religion and Society Interactions
article

Development of an acoustic dose-profile measurement technique for short pulse proton and ion beams

article en

Abstract

Cancer is the second leading cause of death globally, with radiotherapy treating about 50\% of patients. Conventional radiotherapy uses photons, however, it often irradiates healthy cells surrounding the cancerous region. New treatment facilities are turning to protons and light ions, which deposit a maximum dose within a small volume at the end of their range. This thesis introduces LhARA, the Laser-hybrid Accelerator for Radiobiological Applications, which aims to advance radiobiology by exploring how different particle beam characteristics affect therapeutic outcomes. Using pulsed proton and light-ion beams, LhARA offers flexibility in ion species, beam widths, and pulse duration. To minimize uncertainties, real-time dose delivery monitoring is essential. This work presents the SmartPhantom, a novel detector for monitoring three-dimensional dose accumulation delivered using nanosecond-scale ion beam pulses. Unlike existing devices that provide only relative dose values, the SmartPhantom delivers calibrated feedback. The detector uses ultrasound waves induced by the transient pressure increase as the beam propagates through matter. Due to the high speed of ultrasound, feedback is nearly instantaneous. To calibrate the acoustic response, a liquid scintillator is used as the propagating medium inside the detector. The scintillation light emitted during beam propagation, combined with known photon yields, enables absolute dose reconstruction. The SmartPhantom was evaluated at the MC40 cyclotron in Birmingham and the LION accelerator at CALA in Munich. To optimize the design, a simulation pipeline was developed using Python for source parametrization, BDSIM for particle tracking, Geant4 for energy deposition calculations, and Matlab for acoustic modeling. The results revealed strong correlation between optical and acoustic measurements, validating the detector's potential. This lays the foundation for a clinically viable, real-time dose monitoring system.

Imperial College Research Computing Service Data Repository
Imperial College London (GB)
Good health and well-being
Openalex Percentile: Top 37%
Religion and Society Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.