Ultrahigh-sensitivity D-shaped PCF-SPR biosensor with TiO2–Au hybrid layers for precise detection of blood constituents

• A novel D-shaped PCF-based plasmonic biosensor incorporating a thin gold layer as the plasmonic medium and an optimized titanium dioxide dielectric interlayer is presented. • The 3D finite element method simulations are employed to examine the influence of critical design parameters on resonance wavelength and confinement loss. • The proposed sensor achieves an outstanding wavelength sensitivity of 14,000 nm/RIU, amplitude sensitivity (S A ) of 610 RIU −1 , and a resolution of 1.4 × 10 −2 RIU. Plasmonic biosensors based on photonic crystal fibers (PCF-SPR) have emerged as promising candidates for highly sensitive and real-time biomedical detection. In this study, we propose and numerically investigate a novel D-shaped PCF-based plasmonic biosensor incorporating a thin gold layer as the plasmonic medium and an optimized titanium dioxide (TiO 2 ) dielectric interlayer. This configuration significantly enhances light-metal interaction, improves mode confinement, and strengthens surface plasmon resonance (SPR) coupling efficiency. Three-dimensional finite element method (FEM) simulations are employed to examine the influence of critical design parameters, including the thicknesses of Au and TiO 2 layers, air-hole diameters and arrangement, and analyte refractive index (RI) variations, on resonance wavelength and confinement loss. The proposed sensor achieves an outstanding wavelength sensitivity (S λ ) of 14,000 nm/RIU, amplitude sensitivity (S A ) of 610 RIU −1 , and a resolution of 1.4 × 10 −2 RIU within the analyte RI range of 1.33–1.40. These performance metrics enable the discrimination of blood constituents such as water, plasma, hemoglobin, and red and white blood cells, even under conditions of closely matched refractive indices. The findings highlight the remarkable potential of PCF-SPR biosensors for rapid and precise blood analysis, offering new avenues for the advancement of next-generation biomedical diagnostic platforms.

Institutions

Publication Details

Journal
Results in Physics
Published
2025-09-25
DOI
https://doi.org/10.1016/j.rinp.2025.108463
Citations
1
Primary Topic
Rings, Modules, and Algebras
Type
article
Field-Weighted Citation Impact
5.38
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrahigh-sensitivity D-shaped PCF-SPR biosensor with TiO2–Au hybrid layers for precise detection of blood constituents

1 citations
Results in Physics
Rings, Modules, and Algebras
5.38
article

Ultrahigh-sensitivity D-shaped PCF-SPR biosensor with TiO2–Au hybrid layers for precise detection of blood constituents

article en
1 citations

Abstract

• A novel D-shaped PCF-based plasmonic biosensor incorporating a thin gold layer as the plasmonic medium and an optimized titanium dioxide dielectric interlayer is presented. • The 3D finite element method simulations are employed to examine the influence of critical design parameters on resonance wavelength and confinement loss. • The proposed sensor achieves an outstanding wavelength sensitivity of 14,000 nm/RIU, amplitude sensitivity (S A ) of 610 RIU −1 , and a resolution of 1.4 × 10 −2 RIU. Plasmonic biosensors based on photonic crystal fibers (PCF-SPR) have emerged as promising candidates for highly sensitive and real-time biomedical detection. In this study, we propose and numerically investigate a novel D-shaped PCF-based plasmonic biosensor incorporating a thin gold layer as the plasmonic medium and an optimized titanium dioxide (TiO 2 ) dielectric interlayer. This configuration significantly enhances light-metal interaction, improves mode confinement, and strengthens surface plasmon resonance (SPR) coupling efficiency. Three-dimensional finite element method (FEM) simulations are employed to examine the influence of critical design parameters, including the thicknesses of Au and TiO 2 layers, air-hole diameters and arrangement, and analyte refractive index (RI) variations, on resonance wavelength and confinement loss. The proposed sensor achieves an outstanding wavelength sensitivity (S λ ) of 14,000 nm/RIU, amplitude sensitivity (S A ) of 610 RIU −1 , and a resolution of 1.4 × 10 −2 RIU within the analyte RI range of 1.33–1.40. These performance metrics enable the discrimination of blood constituents such as water, plasma, hemoglobin, and red and white blood cells, even under conditions of closely matched refractive indices. The findings highlight the remarkable potential of PCF-SPR biosensors for rapid and precise blood analysis, offering new avenues for the advancement of next-generation biomedical diagnostic platforms.

Results in PhysicsVol. 77
Shahid Rajaee Teacher Training University (IR)
Openalex Percentile: Top 4%
Rings, Modules, and Algebras
5.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ultrahigh-sensitivity D-shaped PCF-SPR biosensor with TiO2–Au hybrid layers for precise detection of blood constituents · Results in Physics (2025) | TGRS Research Map | TGRS