Experimental evaluation of a thermal interface and a cold circulator used in remote cooling loop driven by a cryocooler

Due to helium’s limited accessibility and non-renewable nature, superconducting systems need more sustainable alternatives to cryogenic plants, which feature elevated helium losses. Cryogenic systems based on commercially available cryocoolers are seen as a promising solution. In this paper, a remote cooling loop driven by a cryocooler and cold circulator is introduced, and an experimental study of the heat exchanger serving as the cryocooler-to-gas thermal interface is presented. This thermal interface is intended for integration into a remote cooling system, which is designed to intercept the 300 W heat load from 3 kA hybrid current leads. The heat exchanger successfully maintained a gas outlet temperature below 50 K under 300 W. A mathematical model is developed to forecast both the gas outlet temperatures and the cooling capacity of the heat exchanger for a given geometry, and validation is conducted using experimental data. Furthermore, an experimental verification of the isentropic efficiency of the selected cold circulator is included. Finally, an estimation of the mass flow within the hydraulic system is presented and compared with the measured results. • The study explores cryocoolers as compact, low-maintenance alternatives to cryogenic plants for cooling superconducting magnets. • A remote cooling loop using a single-stage cryocooler and cold circulator is investigated. • A simplified mathematical model for thermal calculations of the cryocooler-to-cryogen thermal interface heat exchanger is developed. • Experimental results for the cryocooler-to-cryogen thermal interface and cold circulator performance are presented.

Institutions

Publication Details

Journal
Cryogenics
Published
2025-09-25
DOI
https://doi.org/10.1016/j.cryogenics.2025.104199
Primary Topic
Viral gastroenteritis research and epidemiology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental evaluation of a thermal interface and a cold circulator used in remote cooling loop driven by a cryocooler

Cryogenics
Viral gastroenteritis research and epidemiology
article

Experimental evaluation of a thermal interface and a cold circulator used in remote cooling loop driven by a cryocooler

article en

Abstract

Due to helium’s limited accessibility and non-renewable nature, superconducting systems need more sustainable alternatives to cryogenic plants, which feature elevated helium losses. Cryogenic systems based on commercially available cryocoolers are seen as a promising solution. In this paper, a remote cooling loop driven by a cryocooler and cold circulator is introduced, and an experimental study of the heat exchanger serving as the cryocooler-to-gas thermal interface is presented. This thermal interface is intended for integration into a remote cooling system, which is designed to intercept the 300 W heat load from 3 kA hybrid current leads. The heat exchanger successfully maintained a gas outlet temperature below 50 K under 300 W. A mathematical model is developed to forecast both the gas outlet temperatures and the cooling capacity of the heat exchanger for a given geometry, and validation is conducted using experimental data. Furthermore, an experimental verification of the isentropic efficiency of the selected cold circulator is included. Finally, an estimation of the mass flow within the hydraulic system is presented and compared with the measured results. • The study explores cryocoolers as compact, low-maintenance alternatives to cryogenic plants for cooling superconducting magnets. • A remote cooling loop using a single-stage cryocooler and cold circulator is investigated. • A simplified mathematical model for thermal calculations of the cryocooler-to-cryogen thermal interface heat exchanger is developed. • Experimental results for the cryocooler-to-cryogen thermal interface and cold circulator performance are presented.

CryogenicsVol. 152
Wrocław University of Science and Technology (PL), European Organization for Nuclear Research (CH), AGH University of Krakow (PL), University of Twente (NL)
CERN
Affordable and clean energy
Openalex Percentile: Top 44%
Viral gastroenteritis research and epidemiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.