Simulation of Radiation Dose Distribution in Radiodiagnostic Facilities Using FLUKA Monte Carlo Code

This study investigates the application of Monte Carlo simulations using the FLUKA code to evaluate the radiation dose distribution in the radiodiagnostic facility of the Fatmawati Medical Check Up Clinic. The objective is to compare the simulation results with experimental measurements and assess the accuracy of the simulation method. The research was carried out in the Physics Modelling Laboratory, Integrated Laboratory of State Islamic University (UIN) Sunan Gunung Djati Bandung, using an HP Proliant ML350P server computer equipped with Intel® Xeon® CPU E5-2620 v2 @ 2.10GHz × 12 cores. The simulation involved modeling the radiation chamber and photon emission plane, configured to emit 9×10⁹ photons at an energy level of 60 keV. Scattered radiation doses were measured at several locations, corresponding to experimental measurement points for validation. The results showed a strong correlation and high level of accuracy between the simulation and experimental data, with a relative error of less than 1%.

Institutions

Publication Details

Journal
Jurnal Phi Jurnal Pendidikan Fisika dan Fisika Terapan
Published
2025-06-30
DOI
https://doi.org/10.22373/hj0xjk86
Primary Topic
Synthesis and Properties of Aromatic Compounds
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of Radiation Dose Distribution in Radiodiagnostic Facilities Using FLUKA Monte Carlo Code

Jurnal Phi Jurnal Pendidikan Fisika dan Fisika Terapan
Synthesis and Properties of Aromatic Compounds
article

Simulation of Radiation Dose Distribution in Radiodiagnostic Facilities Using FLUKA Monte Carlo Code

article en

Abstract

This study investigates the application of Monte Carlo simulations using the FLUKA code to evaluate the radiation dose distribution in the radiodiagnostic facility of the Fatmawati Medical Check Up Clinic. The objective is to compare the simulation results with experimental measurements and assess the accuracy of the simulation method. The research was carried out in the Physics Modelling Laboratory, Integrated Laboratory of State Islamic University (UIN) Sunan Gunung Djati Bandung, using an HP Proliant ML350P server computer equipped with Intel® Xeon® CPU E5-2620 v2 @ 2.10GHz × 12 cores. The simulation involved modeling the radiation chamber and photon emission plane, configured to emit 9×10⁹ photons at an energy level of 60 keV. Scattered radiation doses were measured at several locations, corresponding to experimental measurement points for validation. The results showed a strong correlation and high level of accuracy between the simulation and experimental data, with a relative error of less than 1%.

Jurnal Phi Jurnal Pendidikan Fisika dan Fisika TerapanVol. 11(2)
Sunan Gunung Djati State Islamic University Bandung (ID)
Affordable and clean energy
Openalex Percentile: Top 47%
Synthesis and Properties of Aromatic Compounds
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.