Wearable Microfluidic Dual Screen-Printed Sensor for Simultaneous Monitoring of Sweat pH and Lactate

Sweat lactate monitoring has recently garnered increasing attention for assessing athlete performance, optimizing training, and determining fatigue levels.Thus, this study introduces a wireless dual-biosensor device for continuous monitoring of sweat lactate and pH.The pH sensor exhibits a sensitivity of -61 0.5 mV pH -1 , while the lactate sensor displays a sensitivity of 0.0149 0.0004 mA cm -2 mM -1 at pH 7.5.We establish a method to precisely measure lactate within the pH range of 5.5 to 7.5, taking into account the pH-dependent sensor sensitivity.The dual-biosensor device incorporates polydimethylsiloxane microfluidics for collection of sweat, its delivery to the sensor, and disposal of used sweat, enabling continuous and precise monitoring.On-body tests demonstrate the ability of the proposed device to continuously monitor sweat pH and lactate levels in individuals during exercise.

Institutions

Publication Details

Journal
Electrochemistry
Published
2025-09-24
DOI
https://doi.org/10.5796/electrochemistry.25-00108
Primary Topic
Canadian Policy and Governance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable Microfluidic Dual Screen-Printed Sensor for Simultaneous Monitoring of Sweat pH and Lactate

Electrochemistry
Canadian Policy and Governance
article

Wearable Microfluidic Dual Screen-Printed Sensor for Simultaneous Monitoring of Sweat pH and Lactate

article en

Abstract

Sweat lactate monitoring has recently garnered increasing attention for assessing athlete performance, optimizing training, and determining fatigue levels.Thus, this study introduces a wireless dual-biosensor device for continuous monitoring of sweat lactate and pH.The pH sensor exhibits a sensitivity of -61 0.5 mV pH -1 , while the lactate sensor displays a sensitivity of 0.0149 0.0004 mA cm -2 mM -1 at pH 7.5.We establish a method to precisely measure lactate within the pH range of 5.5 to 7.5, taking into account the pH-dependent sensor sensitivity.The dual-biosensor device incorporates polydimethylsiloxane microfluidics for collection of sweat, its delivery to the sensor, and disposal of used sweat, enabling continuous and precise monitoring.On-body tests demonstrate the ability of the proposed device to continuously monitor sweat pH and lactate levels in individuals during exercise.

ElectrochemistryVol. 93(11)
Tokyo University of Science (JP), Institute of Art (PL), RIKEN Center for Integrative Medical Sciences (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 40%
Canadian Policy and Governance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.