Laser Methane Emission Monitoring Based on Harmonic Ratio Feature and Estimation of Absorption Pulse Parameters

Monitoring of methane from oil and natural gas operations is essential to mitigate environmental risks and promote sustainable practices. The method is an effective tool to detect methane presence and compute methane concentration under condition of low signal to noise ratio. The proposed adaptive time synchronous moving average (ATSMA) and pulse signal fusion of laser signal allow to reduce measurement noise. The proposed ATSMA method reduces the random noise level in terms of root mean square error by 10 times less than the established method. The harmonic ratio features and time–amplitude features improve taking into consideration the properties of the absorption signal and pulse allow to improve the methane estimation accuracy. The proposed method provides linear regression model (R2 = 0.995) with one dependent variable (time–amplitude centroid area of the absorption pulse) for estimating methane concentration for the measured absorption signal.

Institutions

Publication Details

Journal
Instruments and Experimental Techniques
Published
2025-06-01
DOI
https://doi.org/10.1134/s0020441225700526
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laser Methane Emission Monitoring Based on Harmonic Ratio Feature and Estimation of Absorption Pulse Parameters

Instruments and Experimental Techniques
Geochemistry and Geologic Mapping
article

Laser Methane Emission Monitoring Based on Harmonic Ratio Feature and Estimation of Absorption Pulse Parameters

article en

Abstract

Monitoring of methane from oil and natural gas operations is essential to mitigate environmental risks and promote sustainable practices. The method is an effective tool to detect methane presence and compute methane concentration under condition of low signal to noise ratio. The proposed adaptive time synchronous moving average (ATSMA) and pulse signal fusion of laser signal allow to reduce measurement noise. The proposed ATSMA method reduces the random noise level in terms of root mean square error by 10 times less than the established method. The harmonic ratio features and time–amplitude features improve taking into consideration the properties of the absorption signal and pulse allow to improve the methane estimation accuracy. The proposed method provides linear regression model (R2 = 0.995) with one dependent variable (time–amplitude centroid area of the absorption pulse) for estimating methane concentration for the measured absorption signal.

Instruments and Experimental TechniquesVol. 68(3)
Belarusian State University of Informatics and Radioelectronics (BY)
Affordable and clean energy
Openalex Percentile: Top 28%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.