An Analysis of the Unbalanced Three Phase Fault in the Transmission Line

In this paper, unbalanced three-phase fault in transmission lines is considered with respect to estimating the state of power system after a fault occurs at different buses. Faults such as a single-line-to-ground (SLG), line-to-line (LL) and double-line-to-ground (DLG) affect the bus system that is connected along with the transmission line. MATLAB software was employed in which unbalanced fault programs based on the Symmetrical Component method to determine the voltage magnitudes, line current magnitude, total fault current, real and reactive power at Phase A, Phase B and also on phase C for the different bus lines. The unbalanced fault programs are executed using a Newton Raphson based power flow program for the standard IEEE 14, IEEE 26 and IEEE 30 bus systems. The obtained results show that the single line to ground fault is the most severe kind for IEEE 14 bus system, while for IEEE 26 and IEEE 30 bus system, the most severe fault is line to line fault. This finding is crucial for evaluating the reliability and stability of power transmission lines.

Institutions

Publication Details

Journal
International Journal of Electrical Engineering and Applied Sciences (IJEEAS)
Published
2025-04-30
DOI
https://doi.org/10.54554/ijeeas.2025.8.01.004
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Analysis of the Unbalanced Three Phase Fault in the Transmission Line

International Journal of Electrical Engineering and Applied Sciences (IJEEAS)
Geochemistry and Geologic Mapping
article

An Analysis of the Unbalanced Three Phase Fault in the Transmission Line

article en

Abstract

In this paper, unbalanced three-phase fault in transmission lines is considered with respect to estimating the state of power system after a fault occurs at different buses. Faults such as a single-line-to-ground (SLG), line-to-line (LL) and double-line-to-ground (DLG) affect the bus system that is connected along with the transmission line. MATLAB software was employed in which unbalanced fault programs based on the Symmetrical Component method to determine the voltage magnitudes, line current magnitude, total fault current, real and reactive power at Phase A, Phase B and also on phase C for the different bus lines. The unbalanced fault programs are executed using a Newton Raphson based power flow program for the standard IEEE 14, IEEE 26 and IEEE 30 bus systems. The obtained results show that the single line to ground fault is the most severe kind for IEEE 14 bus system, while for IEEE 26 and IEEE 30 bus system, the most severe fault is line to line fault. This finding is crucial for evaluating the reliability and stability of power transmission lines.

International Journal of Electrical Engineering and Applied Sciences (IJEEAS)Vol. 8(1)
University of Selangor (MY)
Affordable and clean energy
Openalex Percentile: Top 28%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.