Degradation Behavior of a Fe-based Amorphous Coating Prepared by Cold Spraying

Although magnesium and magnesium alloys are known as biodegradable medical metals with proper mechanical properties and bio-compatibility, the rapid degradation rate limits their clinical applications. In this paper, Fe78Si9B13 amorphous coatings were prepared on the surface of ZK60A magnesium alloy by using the cold gas dynamic spraying (CGDS) technology. Microstructure, mechanical properties, corrosion resistance, and the degradation behavior of the coatings were investigated. Results show that the coating prepared at 5 MPa and 1073 K has the maximum coating thickness, the lowest porosity, the highest microhardness and contact angle, the most positive corrosion potential, the smallest corrosion current density, and a relatively high volume fraction of amorphous phase. Immersion corrosion experiments show that the degradation rate of the optimal coating is 0.15 mm/a, meeting the requirement of the bone implant material. Degradation behavior analysis shows that bone-like apatite nucleates and rapidly grows into bone-like hydroxyapatite when the sample is immersed in simulated body fluids solution for several days, demonstrating strong biological activity and osteoinductivity of the coating. Furthermore, although pits occurred, electrochemical impedance spectra shows that the coating still keeps a good corrosion resistance immersed in SBF for 15 days.

Institutions

Publication Details

Journal
MATERIALS TRANSACTIONS
Published
2025-09-24
DOI
https://doi.org/10.2320/matertrans.mt-m2025061
Primary Topic
Prenatal Screening and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Degradation Behavior of a Fe-based Amorphous Coating Prepared by Cold Spraying

MATERIALS TRANSACTIONS
Prenatal Screening and Diagnostics
article

Degradation Behavior of a Fe-based Amorphous Coating Prepared by Cold Spraying

article en

Abstract

Although magnesium and magnesium alloys are known as biodegradable medical metals with proper mechanical properties and bio-compatibility, the rapid degradation rate limits their clinical applications. In this paper, Fe78Si9B13 amorphous coatings were prepared on the surface of ZK60A magnesium alloy by using the cold gas dynamic spraying (CGDS) technology. Microstructure, mechanical properties, corrosion resistance, and the degradation behavior of the coatings were investigated. Results show that the coating prepared at 5 MPa and 1073 K has the maximum coating thickness, the lowest porosity, the highest microhardness and contact angle, the most positive corrosion potential, the smallest corrosion current density, and a relatively high volume fraction of amorphous phase. Immersion corrosion experiments show that the degradation rate of the optimal coating is 0.15 mm/a, meeting the requirement of the bone implant material. Degradation behavior analysis shows that bone-like apatite nucleates and rapidly grows into bone-like hydroxyapatite when the sample is immersed in simulated body fluids solution for several days, demonstrating strong biological activity and osteoinductivity of the coating. Furthermore, although pits occurred, electrochemical impedance spectra shows that the coating still keeps a good corrosion resistance immersed in SBF for 15 days.

MATERIALS TRANSACTIONSVol. 66(10)
Wenzhou University (CN), Lanzhou University of Technology (CN), Dongfang Electric Corporation (China) (CN)
Openalex Percentile: Top 31%
Prenatal Screening and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.