Image quality and dose reduction in cardiac interventional procedures: application of an optimization strategy with typical dose value analysis

This study aimed to evaluate the impact of dose‑optimization strategies on radiation exposure during cardiac catheterization and angioplasty procedures. The investigation was carried out at a high‑complexity referral center using retrospective data, clinical‑protocol adjustments, and image‑quality assessments with dedicated simulators. Implemented measures included reducing the cine dose per frame and enabling post‑processing filters, resulting in reductions of up to 39 % in reference‑point kerma and 25 % in noise intensity under low‑dose conditions. In total, 714 procedures performed over five semesters were analyzed. Diagnostic reference levels (DRLs) were determined and compared with data from national and international literature. A statistically significant reduction in DAP (16.3 %) and Kₐ,r (12.8 %) was observed for catheterization procedures (p < 0.05). Although angioplasty procedures showed a similar trend, case variability limited statistical significance. The results demonstrate the effectiveness of technical interventions and continuous monitoring in lowering exposure levels, without compromising diagnostic image quality.

Institutions

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2025-09-24
DOI
https://doi.org/10.15392/2319-0612.2025.2943
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Image quality and dose reduction in cardiac interventional procedures: application of an optimization strategy with typical dose value analysis

Brazilian Journal of Radiation Sciences
Geochemistry and Geologic Mapping
article

Image quality and dose reduction in cardiac interventional procedures: application of an optimization strategy with typical dose value analysis

article en

Abstract

This study aimed to evaluate the impact of dose‑optimization strategies on radiation exposure during cardiac catheterization and angioplasty procedures. The investigation was carried out at a high‑complexity referral center using retrospective data, clinical‑protocol adjustments, and image‑quality assessments with dedicated simulators. Implemented measures included reducing the cine dose per frame and enabling post‑processing filters, resulting in reductions of up to 39 % in reference‑point kerma and 25 % in noise intensity under low‑dose conditions. In total, 714 procedures performed over five semesters were analyzed. Diagnostic reference levels (DRLs) were determined and compared with data from national and international literature. A statistically significant reduction in DAP (16.3 %) and Kₐ,r (12.8 %) was observed for catheterization procedures (p < 0.05). Although angioplasty procedures showed a similar trend, case variability limited statistical significance. The results demonstrate the effectiveness of technical interventions and continuous monitoring in lowering exposure levels, without compromising diagnostic image quality.

Brazilian Journal of Radiation SciencesVol. 13(3)
Instituto Federal de Goiás (BR), Elabora Consultoria (Brazil) (BR), Universidade Federal de Goiás (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Openalex Percentile: Top 28%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.