OPTIMIZING DOUBLE SKIN FAÇADE GLAZING FOR ENERGY EFFICIENCY IN SHOPPING MALL DESIGN: A CASE STUDY OF JAHI, ABUJA

This study evaluates the effectiveness of double skin façade (DSF) glazing systems in improving energy efficiency in shopping mall buildings within Abuja’s hot-humid climate. Using building performance simulations, the energy demands of various glazing configurations thermochromic, low-emissivity (low-E), tinted, and clear glass in single, double, and triple panes were compared against a base case model without DSF. Results reveal that thermochromic glazing and low-E double-pane glass achieved the greatest reductions in annual cooling energy demand, lowering consumption by up to 14% compared to conventional façades. Conversely, single-pane and untreated clear glazing exhibited the poorest performance. The study demonstrates that DSF systems optimized with climate-specific glazing significantly enhance thermal regulation, reduce cooling loads, and support sustainable commercial architecture in Nigeria.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-09-24
DOI
https://doi.org/10.5281/zenodo.17190395
Primary Topic
Diverse Scientific and Economic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OPTIMIZING DOUBLE SKIN FAÇADE GLAZING FOR ENERGY EFFICIENCY IN SHOPPING MALL DESIGN: A CASE STUDY OF JAHI, ABUJA

Zenodo (CERN European Organization for Nuclear Research)
Diverse Scientific and Economic Studies
article

OPTIMIZING DOUBLE SKIN FAÇADE GLAZING FOR ENERGY EFFICIENCY IN SHOPPING MALL DESIGN: A CASE STUDY OF JAHI, ABUJA

article en

Abstract

This study evaluates the effectiveness of double skin façade (DSF) glazing systems in improving energy efficiency in shopping mall buildings within Abuja’s hot-humid climate. Using building performance simulations, the energy demands of various glazing configurations thermochromic, low-emissivity (low-E), tinted, and clear glass in single, double, and triple panes were compared against a base case model without DSF. Results reveal that thermochromic glazing and low-E double-pane glass achieved the greatest reductions in annual cooling energy demand, lowering consumption by up to 14% compared to conventional façades. Conversely, single-pane and untreated clear glazing exhibited the poorest performance. The study demonstrates that DSF systems optimized with climate-specific glazing significantly enhance thermal regulation, reduce cooling loads, and support sustainable commercial architecture in Nigeria.

Zenodo (CERN European Organization for Nuclear Research)
Bingham University (NG)
Affordable and clean energy
Openalex Percentile: Top 35%
Diverse Scientific and Economic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.