A VALIDATED RP-HPLC METHOD FOR ESTIMATION OF RIVAROXABAN IN BULK AND TABLET DOSAGE FORM

A simple, rapid, precise, sensitive and reproducible reverse phase high performance liquid chromatography (RP-HPLC) method has been developed for the quantitative analysis of Rivaroxaban in pharmaceutical dosage form. Chromatographic separation of Rivaroxaban was achieved on Prominence LC-20A Quaternary Gradient HPLC system, by using Shimpack C-18 (5μm, 4.6 x 250mm) column and the mobile phase containing Acetonitrile and Phosphate Buffer with pH of 4.5 in a 50:50 v/v ratio. The flow rate was 1.0ml/min; detection was carried out by absorption at 235nm using a UV detector at ambient temperature. LOD and LOQ were found to be 0.7497μg/ml and 2.272μg/ml respectively and retention time was found to be 4.848mins. The % Recovery was found to be 100.70-101.37%. The number of theoretical plates and tailing factor for Rivaroxaban were not less than 2000 and not more than 2 respectively. % Relative standard deviation of peak areas of all measurements always less than 2.0. The proposed method was validated according to ICH guidelines. The method was found to be simple, economical, suitable, precise, accurate and robust method for quantitative analysis of Rivaroxaban.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-09-24
DOI
https://doi.org/10.5281/zenodo.17192912
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A VALIDATED RP-HPLC METHOD FOR ESTIMATION OF RIVAROXABAN IN BULK AND TABLET DOSAGE FORM

Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Geologic Mapping
article

A VALIDATED RP-HPLC METHOD FOR ESTIMATION OF RIVAROXABAN IN BULK AND TABLET DOSAGE FORM

article en

Abstract

A simple, rapid, precise, sensitive and reproducible reverse phase high performance liquid chromatography (RP-HPLC) method has been developed for the quantitative analysis of Rivaroxaban in pharmaceutical dosage form. Chromatographic separation of Rivaroxaban was achieved on Prominence LC-20A Quaternary Gradient HPLC system, by using Shimpack C-18 (5μm, 4.6 x 250mm) column and the mobile phase containing Acetonitrile and Phosphate Buffer with pH of 4.5 in a 50:50 v/v ratio. The flow rate was 1.0ml/min; detection was carried out by absorption at 235nm using a UV detector at ambient temperature. LOD and LOQ were found to be 0.7497μg/ml and 2.272μg/ml respectively and retention time was found to be 4.848mins. The % Recovery was found to be 100.70-101.37%. The number of theoretical plates and tailing factor for Rivaroxaban were not less than 2000 and not more than 2 respectively. % Relative standard deviation of peak areas of all measurements always less than 2.0. The proposed method was validated according to ICH guidelines. The method was found to be simple, economical, suitable, precise, accurate and robust method for quantitative analysis of Rivaroxaban.

Zenodo (CERN European Organization for Nuclear Research)
Bharathiar University (IN), Bharat Electronics (India) (IN)
Openalex Percentile: Top 29%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A VALIDATED RP-HPLC METHOD FOR ESTIMATION OF RIVAROXABAN IN BULK AND TABLET DOSAGE FORM · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS