Self-Expanding Versus Balloon-Expandable Transcatheter Heart Valves in Patients with Excessive Aortic Valve Cusp Calcification.

Background Excessive aortic cusp calcification increases the risk of periprocedural complications after transcatheter aortic valve replacement (TAVR). Differences in device performance in patients with excessive calcification may affect long-term clinical outcomes.Objectives To compare periprocedural and long-term outcomes between self-expanding (SEV) and balloon-expandable (BEV) prostheses in patients with excess cusp calcification undergoing TAVR.Methods Consecutive patients with severe aortic stenosis and aortic valve complex calcium volume ≥235 mm³ (on contrast images with Hounsfield unit threshold of 850) who underwent TAVR with either CoreValve/Evolut SEV or SAPIEN BEV from August 2007 to June 2023 were included from a prospective-single center registry. A 1:1 propensity-matched analysis was performed to account for baseline differences between groups.Results Among 1,345 patients, 271 matched pairs were identified. Procedural success was achieved in >85% of patients with no difference between groups. Annular rupture occurred more frequently with BEV compared to SEV (2.2% vs 0%, p=0.030). SEV had a lower transprosthetic gradient (8.0 mmHg vs. 11.2 mmHg, p <0.001) but higher rates of mild or greater paravalvular regurgitation (69.7% vs. 58.1%, p=0.008) and new permanent pacemaker implantation (22.6% vs. 15.5%, p=0.001). At 5 years, there was no statistically significant difference in mortality between groups (45.1% vs. 50.2%, p=0.173).Conclusions In patients with excessive leaflet calcification undergoing TAVR, BEV had a higher risk of annular rupture, but a lower risk of paravalvular regurgitation, and a lower risk of permanent pacemaker implantation compared to SEV. Mortality was comparable between SEV and BEV throughout 5 years of follow-up.Clinical Trial Registration https://www.Clinicaltrials gov. NCT01368250.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-09-18
DOI
https://doi.org/10.48620/91469
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Expanding Versus Balloon-Expandable Transcatheter Heart Valves in Patients with Excessive Aortic Valve Cusp Calcification.

Open Access CRIS of the University of Bern
Geochemistry and Geologic Mapping
article

Self-Expanding Versus Balloon-Expandable Transcatheter Heart Valves in Patients with Excessive Aortic Valve Cusp Calcification.

article en

Abstract

Background Excessive aortic cusp calcification increases the risk of periprocedural complications after transcatheter aortic valve replacement (TAVR). Differences in device performance in patients with excessive calcification may affect long-term clinical outcomes.Objectives To compare periprocedural and long-term outcomes between self-expanding (SEV) and balloon-expandable (BEV) prostheses in patients with excess cusp calcification undergoing TAVR.Methods Consecutive patients with severe aortic stenosis and aortic valve complex calcium volume ≥235 mm³ (on contrast images with Hounsfield unit threshold of 850) who underwent TAVR with either CoreValve/Evolut SEV or SAPIEN BEV from August 2007 to June 2023 were included from a prospective-single center registry. A 1:1 propensity-matched analysis was performed to account for baseline differences between groups.Results Among 1,345 patients, 271 matched pairs were identified. Procedural success was achieved in >85% of patients with no difference between groups. Annular rupture occurred more frequently with BEV compared to SEV (2.2% vs 0%, p=0.030). SEV had a lower transprosthetic gradient (8.0 mmHg vs. 11.2 mmHg, p <0.001) but higher rates of mild or greater paravalvular regurgitation (69.7% vs. 58.1%, p=0.008) and new permanent pacemaker implantation (22.6% vs. 15.5%, p=0.001). At 5 years, there was no statistically significant difference in mortality between groups (45.1% vs. 50.2%, p=0.173).Conclusions In patients with excessive leaflet calcification undergoing TAVR, BEV had a higher risk of annular rupture, but a lower risk of paravalvular regurgitation, and a lower risk of permanent pacemaker implantation compared to SEV. Mortality was comparable between SEV and BEV throughout 5 years of follow-up.Clinical Trial Registration https://www.Clinicaltrials gov. NCT01368250.

Open Access CRIS of the University of Bern
United Heart and Vascular Clinic (US), IST Research (US)
Good health and well-being
Openalex Percentile: Top 29%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.