Features of transition of hybrid inverters to standalone mode with induction motors

Purpose. To study the operating modes of a hybrid inverter with an active-inductive load and a reduced power factor due to the starting modes of induction motors in both standalone and grid-connected modes. Methodology. Experimental methods were applied, including the use of an industrial power quality analyzer and investigation of a real solar power plant based on a hybrid inverter with an energy storage system and photovoltaic modules. Results. The study revealed specific features of the transient process, represented as current and voltage oscillograms with significant waveform distortions during switching. These distortions indicate the potential hazards of operating asynchronous motors and hybrid inverters during mode transitions, i.e., switching from autonomous to grid-connected mode and vice versa. This is associated with the asynchronous motor entering a generator mode during machine run-down. The obtained results clearly demonstrate that systems based on hybrid inverters are sufficiently stable to withstand complex transient processes under dynamic active-inductive loads. However, voltage waveform distortions can trigger malfunctions in other protective devices and electrical equipment operating on the same bus. Scientific novelty. The novelty lies in identifying the features of transient processes in inverter equipment with active-inductive loads and the variation of key electrical parameters depending on the ratio between inverter power and load power. The study establishes the dependence of the inverter cascade stability on the reactive power levels at the moment of asynchronous motor start-up, with reference to the permissible inverter power factor values during the transition from grid-supplied to inverter-supplied operation. Practical significance. In justifying the use of additional power conversion equipment for operating induction motors with potential backup power from hybrid inverters, as well as in searching for technical solutions for current limiting during transitions from grid-supplied operation to inverter-supplied operation.

Publication Details

Journal
Collection of Research Papers of the National Mining University
Published
2025-06-30
DOI
https://doi.org/10.33271/crpnmu/81.159
Primary Topic
Geodetic Measurements and Engineering Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Features of transition of hybrid inverters to standalone mode with induction motors

Collection of Research Papers of the National Mining University
Geodetic Measurements and Engineering Structures
article

Features of transition of hybrid inverters to standalone mode with induction motors

article en

Abstract

Purpose. To study the operating modes of a hybrid inverter with an active-inductive load and a reduced power factor due to the starting modes of induction motors in both standalone and grid-connected modes. Methodology. Experimental methods were applied, including the use of an industrial power quality analyzer and investigation of a real solar power plant based on a hybrid inverter with an energy storage system and photovoltaic modules. Results. The study revealed specific features of the transient process, represented as current and voltage oscillograms with significant waveform distortions during switching. These distortions indicate the potential hazards of operating asynchronous motors and hybrid inverters during mode transitions, i.e., switching from autonomous to grid-connected mode and vice versa. This is associated with the asynchronous motor entering a generator mode during machine run-down. The obtained results clearly demonstrate that systems based on hybrid inverters are sufficiently stable to withstand complex transient processes under dynamic active-inductive loads. However, voltage waveform distortions can trigger malfunctions in other protective devices and electrical equipment operating on the same bus. Scientific novelty. The novelty lies in identifying the features of transient processes in inverter equipment with active-inductive loads and the variation of key electrical parameters depending on the ratio between inverter power and load power. The study establishes the dependence of the inverter cascade stability on the reactive power levels at the moment of asynchronous motor start-up, with reference to the permissible inverter power factor values during the transition from grid-supplied to inverter-supplied operation. Practical significance. In justifying the use of additional power conversion equipment for operating induction motors with potential backup power from hybrid inverters, as well as in searching for technical solutions for current limiting during transitions from grid-supplied operation to inverter-supplied operation.

Collection of Research Papers of the National Mining UniversityVol. 81
Affordable and clean energy
Openalex Percentile: Top 51%
Geodetic Measurements and Engineering Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Features of transition of hybrid inverters to standalone mode with induction motors · Collection of Research Papers of the National Mining University (2025) | TGRS Research Map | TGRS