Incorporating fluid-structure interactions for modelling of pyramidal hollow microneedles for transdermal drug delivery

Hollow microneedles (HMNs) have gained significant attention as a potential alternative to traditional hypodermic needles for delivering drugs through the skin. The rational selection of the HMN geometry and materials is essential for balancing the MN's mechanical stability and efficient drug delivery. In addressing this, the current study aims to develop a numerical model for fluid-structure interactions (FSI) in hollow pyramidal-shaped MNs where HMNs made from two polymers (polylactic acid (PLA) and polyglycolic acid (PGA)) and one metal (stainless steel (SS)) are considered. Finite element (FE) simulations have been performed with COMSOL 6.2 Multiphysics to determine the effect of MN design parameters such as wall thickness, pitch, channel diameter, and dual-zone MN structure (different MN lengths) on fluid flow and von Mises stress distribution in the HMNs. The FSI analysis has been conducted for a laminar flow of water-fentanyl mixture as a model fluid. The findings revealed that raising the inlet pressure from 10 kPa to 30 kPa at the HMN entrance increases the flow rate to 0.005 μl/s, velocity 0.003 m/s, and total drug flux by 248.63%. As expected, SS demonstrated the lowest von Mises stress (13213 N/m 2 ) while PLA and PGA exhibited a decrease in the stress level as the HMN wall thickness increased. Increasing the MN pitch from 400 μm to 1200 μm reduced skin pore pressure by 72% and enhanced drug concentration by 11.4%. The dual-zone MN arrangement, combining shorter and longer needles, improved the HMN penetration and led to a 90.8% increase in overall flux. These findings provide a foundation for optimising HMN designs, ensuring a balance between mechanical stability and improved transdermal drug diffusion for clinical applications. • Studied fluid-structure interaction in hollow pyramid-shaped MNs. • Increased MN pitch decreased pore pressure by 72% and improved drug concentration. • Higher inlet pressure improved flow rate, velocity, and overall drug permeability. • SS demonstrated the highest stability with the lowest stress of 13,213 N/m 2 under fluid pressure.

Institutions

Publication Details

Journal
Journal of Drug Delivery Science and Technology
Published
2025-09-23
DOI
https://doi.org/10.1016/j.jddst.2025.107561
Citations
2
Primary Topic
Data Analysis with R
Type
article
Field-Weighted Citation Impact
4.96
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incorporating fluid-structure interactions for modelling of pyramidal hollow microneedles for transdermal drug delivery

2 citations
Journal of Drug Delivery Science and Technology
Data Analysis with R
4.96
article

Incorporating fluid-structure interactions for modelling of pyramidal hollow microneedles for transdermal drug delivery

article en
2 citations

Abstract

Hollow microneedles (HMNs) have gained significant attention as a potential alternative to traditional hypodermic needles for delivering drugs through the skin. The rational selection of the HMN geometry and materials is essential for balancing the MN's mechanical stability and efficient drug delivery. In addressing this, the current study aims to develop a numerical model for fluid-structure interactions (FSI) in hollow pyramidal-shaped MNs where HMNs made from two polymers (polylactic acid (PLA) and polyglycolic acid (PGA)) and one metal (stainless steel (SS)) are considered. Finite element (FE) simulations have been performed with COMSOL 6.2 Multiphysics to determine the effect of MN design parameters such as wall thickness, pitch, channel diameter, and dual-zone MN structure (different MN lengths) on fluid flow and von Mises stress distribution in the HMNs. The FSI analysis has been conducted for a laminar flow of water-fentanyl mixture as a model fluid. The findings revealed that raising the inlet pressure from 10 kPa to 30 kPa at the HMN entrance increases the flow rate to 0.005 μl/s, velocity 0.003 m/s, and total drug flux by 248.63%. As expected, SS demonstrated the lowest von Mises stress (13213 N/m 2 ) while PLA and PGA exhibited a decrease in the stress level as the HMN wall thickness increased. Increasing the MN pitch from 400 μm to 1200 μm reduced skin pore pressure by 72% and enhanced drug concentration by 11.4%. The dual-zone MN arrangement, combining shorter and longer needles, improved the HMN penetration and led to a 90.8% increase in overall flux. These findings provide a foundation for optimising HMN designs, ensuring a balance between mechanical stability and improved transdermal drug diffusion for clinical applications. • Studied fluid-structure interaction in hollow pyramid-shaped MNs. • Increased MN pitch decreased pore pressure by 72% and improved drug concentration. • Higher inlet pressure improved flow rate, velocity, and overall drug permeability. • SS demonstrated the highest stability with the lowest stress of 13,213 N/m 2 under fluid pressure.

Journal of Drug Delivery Science and TechnologyVol. 114
Queen's University Belfast (GB), Loughborough University (GB)
Good health and well-being
Openalex Percentile: Top 4%
Data Analysis with R
4.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.