Analysis of the active fire protection system at the head office of Perumda Air Minum Surya Sembada in Surabaya City

Regional drinking water companies are regionally owned business units engaged in the distribution of clean water for public needs. One of the potential hazards and risks that may occur in office buildings is fire. Operational disruptions caused by fires can have widespread impacts, including disturbances in the distribution of clean water to customers. Therefore, this study aims to evaluate the implementation of the active fire protection system at the Head Office of Perumda Air Minum Surya Sembada, Surabaya, as an effort toward fire prevention and mitigation. This research employs a qualitative method with a descriptive observational approach. The results indicate that the compliance level of fire detectors, based on SNI 03-3985-2000, is 83%, which is classified as good. The compliance level of fire alarms, based on SNI 03-3985-2000, is also 83%, which is classified as good. The compliance level of sprinkler systems, based on SNI 03-3989-2000, is 70%, which is classified as fairly good. The compliance level of fire extinguishers, based on the Ministry of Labour and Transmigration Regulation No. Per. 04/MEN/1980, is 75%, which is classified as fairly good. The compliance level of hydrants, based on SNI 03-1745-2000, is 89%, which is classified as good. Thus, the overall compliance level of the active fire protection system implementation at the Head Office of Perumda Air Minum Surya Sembada, Surabaya, is 80%, which falls into the "fairly good" category.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-03-30
DOI
https://doi.org/10.5281/zenodo.17173025
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the active fire protection system at the head office of Perumda Air Minum Surya Sembada in Surabaya City

Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Geologic Mapping
article

Analysis of the active fire protection system at the head office of Perumda Air Minum Surya Sembada in Surabaya City

article en

Abstract

Regional drinking water companies are regionally owned business units engaged in the distribution of clean water for public needs. One of the potential hazards and risks that may occur in office buildings is fire. Operational disruptions caused by fires can have widespread impacts, including disturbances in the distribution of clean water to customers. Therefore, this study aims to evaluate the implementation of the active fire protection system at the Head Office of Perumda Air Minum Surya Sembada, Surabaya, as an effort toward fire prevention and mitigation. This research employs a qualitative method with a descriptive observational approach. The results indicate that the compliance level of fire detectors, based on SNI 03-3985-2000, is 83%, which is classified as good. The compliance level of fire alarms, based on SNI 03-3985-2000, is also 83%, which is classified as good. The compliance level of sprinkler systems, based on SNI 03-3989-2000, is 70%, which is classified as fairly good. The compliance level of fire extinguishers, based on the Ministry of Labour and Transmigration Regulation No. Per. 04/MEN/1980, is 75%, which is classified as fairly good. The compliance level of hydrants, based on SNI 03-1745-2000, is 89%, which is classified as good. Thus, the overall compliance level of the active fire protection system implementation at the Head Office of Perumda Air Minum Surya Sembada, Surabaya, is 80%, which falls into the "fairly good" category.

Zenodo (CERN European Organization for Nuclear Research)
Universitas Airlangga (ID)
Openalex Percentile: Top 31%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of the active fire protection system at the head office of Perumda Air Minum Surya Sembada in Surabaya City · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS