Quantitative In Vivo Cherenkov Luminescence Imaging and Dosimetry of Yttrium-86-NM600

Purpose: The expansion of radiopharmaceutical therapy (RPT) development demands scalable preclinical dosimetry methods. While PET and SPECT remain the gold standards, their low throughput and high cost limit large-cohort studies. Cherenkov luminescence imaging (CLI) offers a high-throughput alternative but suffers from depth-dependent attenuation and photon scatter that compromise quantitative accuracy. This work develops and validates a quantitative CLI methodology incorporating attenuation and scatter corrections for accurate preclinical dosimetry. Methods: Depth-dependent attenuation was characterized using a tissue-mimicking phantom to derive calibration coefficients. Photon scatter was modeled using GEANT4-generated Cherenkov spread functions (CSFs), applied in a depth-weighted iterative Richardson--Lucy deconvolution/reconvolution framework. The method was evaluated in NU/NU mice (n=4) bearing MC38 tumors after injection of $^{86}$Y-NM600, an isotope suitable for both PET and CLI. Liver and tumor activities were quantified at four timepoints using PET and the proposed CLI method. Monte Carlo dosimetry was performed for both modalities. Results: CLI--PET activity quantification yielded mean errors of 15.4% (liver) and 10.3% (tumor) over the first three timepoints. Tumor absorbed doses from CLI-derived synthetic PET images (3.4 $\pm$ 0.3 Gy/MBq) were statistically indistinguishable from PET-based estimates (3.2 $\pm$ 0.2 Gy/MBq, $p=0.31$). Discrepancies increased at late timepoints due to low activity and background auto-luminescence. Conclusions: With appropriate depth-dependent attenuation calibration and Monte Carlo--derived scatter correction, CLI can provide quantitative biodistribution and dosimetry estimates comparable to PET. This approach enables high-throughput, low-cost in vivo dosimetry, expanding the feasibility of large-scale preclinical RPT studies.

Publication Details

Journal
ArXiv.org
Published
2025-09-16
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative In Vivo Cherenkov Luminescence Imaging and Dosimetry of Yttrium-86-NM600

ArXiv.org
Geochemistry and Geologic Mapping
article

Quantitative In Vivo Cherenkov Luminescence Imaging and Dosimetry of Yttrium-86-NM600

article en

Abstract

Purpose: The expansion of radiopharmaceutical therapy (RPT) development demands scalable preclinical dosimetry methods. While PET and SPECT remain the gold standards, their low throughput and high cost limit large-cohort studies. Cherenkov luminescence imaging (CLI) offers a high-throughput alternative but suffers from depth-dependent attenuation and photon scatter that compromise quantitative accuracy. This work develops and validates a quantitative CLI methodology incorporating attenuation and scatter corrections for accurate preclinical dosimetry. Methods: Depth-dependent attenuation was characterized using a tissue-mimicking phantom to derive calibration coefficients. Photon scatter was modeled using GEANT4-generated Cherenkov spread functions (CSFs), applied in a depth-weighted iterative Richardson--Lucy deconvolution/reconvolution framework. The method was evaluated in NU/NU mice (n=4) bearing MC38 tumors after injection of $^{86}$Y-NM600, an isotope suitable for both PET and CLI. Liver and tumor activities were quantified at four timepoints using PET and the proposed CLI method. Monte Carlo dosimetry was performed for both modalities. Results: CLI--PET activity quantification yielded mean errors of 15.4% (liver) and 10.3% (tumor) over the first three timepoints. Tumor absorbed doses from CLI-derived synthetic PET images (3.4 $\pm$ 0.3 Gy/MBq) were statistically indistinguishable from PET-based estimates (3.2 $\pm$ 0.2 Gy/MBq, $p=0.31$). Discrepancies increased at late timepoints due to low activity and background auto-luminescence. Conclusions: With appropriate depth-dependent attenuation calibration and Monte Carlo--derived scatter correction, CLI can provide quantitative biodistribution and dosimetry estimates comparable to PET. This approach enables high-throughput, low-cost in vivo dosimetry, expanding the feasibility of large-scale preclinical RPT studies.

ArXiv.org
Openalex Percentile: Top 32%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantitative In Vivo Cherenkov Luminescence Imaging and Dosimetry of Yttrium-86-NM600 · ArXiv.org (2025) | TGRS Research Map | TGRS