Performance evaluation of digital morphology analyzer CellaVision DM1200

Introduction: For white blood cell (WBC) differentials, manual counting is the standard method, but blood smears can now be automatically analyzed thanks to advancements in digital imaging technologies. In this study, we aimed to evaluate the performance of CellaVision DM1200 on white blood cell differentials and erythrocyte abnormalities, using blood smears from normal and abnormal samples. The pre-classification and reclassification of WBCs by CellaVision were compared to the reference manual count. Methods: Our evaluation for CELLAVISION DM1200 took several steps initiating by precision which includes repeatability and reproducibility. The accuracy was determined by comparison of results between the optical microscope and CELLAVISION DM1200, using Passing Bablok regression analysis. We also studied the ability of the CellaVision DM1200 system to identify clinically important abnormalities compared with manual microscopic differential counting by calculating sensitivity and specificity. Red blood cells were also evaluated by studying sensitivity and specificity. Results: Repeatability and reproducibility showed acceptable results. Regarding the comparability between the optical microscope and CELLAVISION DM1200, post-classification showed good results compared to pre-classification. Evaluation of color, size, and morphology abnormalities of RBCs showed good results. Conclusion: After verification, the CELLAVISION DM1200's performance for WBC differential and detection of abnormalities of RBCs appears to be satisfactory, even in abnormal samples. However, CELLAVISION DM1200 cannot fully replace manual WBC differential counting, reclassification and slide review are still required in abnormal samples.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-04-30
DOI
https://doi.org/10.5281/zenodo.17164119
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of digital morphology analyzer CellaVision DM1200

Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Geologic Mapping
article

Performance evaluation of digital morphology analyzer CellaVision DM1200

article en

Abstract

Introduction: For white blood cell (WBC) differentials, manual counting is the standard method, but blood smears can now be automatically analyzed thanks to advancements in digital imaging technologies. In this study, we aimed to evaluate the performance of CellaVision DM1200 on white blood cell differentials and erythrocyte abnormalities, using blood smears from normal and abnormal samples. The pre-classification and reclassification of WBCs by CellaVision were compared to the reference manual count. Methods: Our evaluation for CELLAVISION DM1200 took several steps initiating by precision which includes repeatability and reproducibility. The accuracy was determined by comparison of results between the optical microscope and CELLAVISION DM1200, using Passing Bablok regression analysis. We also studied the ability of the CellaVision DM1200 system to identify clinically important abnormalities compared with manual microscopic differential counting by calculating sensitivity and specificity. Red blood cells were also evaluated by studying sensitivity and specificity. Results: Repeatability and reproducibility showed acceptable results. Regarding the comparability between the optical microscope and CELLAVISION DM1200, post-classification showed good results compared to pre-classification. Evaluation of color, size, and morphology abnormalities of RBCs showed good results. Conclusion: After verification, the CELLAVISION DM1200's performance for WBC differential and detection of abnormalities of RBCs appears to be satisfactory, even in abnormal samples. However, CELLAVISION DM1200 cannot fully replace manual WBC differential counting, reclassification and slide review are still required in abnormal samples.

Zenodo (CERN European Organization for Nuclear Research)
Centre Hospitalier Universitaire Mohammed VI (MA)
Openalex Percentile: Top 33%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance evaluation of digital morphology analyzer CellaVision DM1200 · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS