VasoTracker 2 : open-source software and hardware for tracking blood vessel diameter and assessing vascular function

VasoTracker 2 is a collection of open‐source tools for blood vessel diameter measurement and vascular physiology research, featuring automated diameter tracking software and low‐cost myography hardware components. This blood vessel analysis platform addresses the need for accessible alternatives to expensive commercial vascular imaging systems by providing comprehensive tools for studying vessel reactivity and endothelial function. The software enables multipoint diameter tracking in branched vessels using advanced edge detection algorithms, supporting brightfield microscopy, fluorescence imaging and ultrasound recordings. Automated pressure protocols enable standardized myogenic tone experiments, and both real‐time and offline analysis of pre‐recorded data are supported. The platform's versatility allows researchers to study vascular dynamics across diverse experimental conditions, from isolated vessel preparations to in vivo imaging applications. For ex vivo applications, VasoTracker 2 includes modular, low‐cost open‐source pressure myograph hardware: a confocal‐compatible vessel chamber and a programmable pressure controller, VasoMoto. These components enable construction of a complete pressure myograph system at a significantly reduced cost compared to commercial alternatives. The hardware integrates seamlessly with the diameter measurement software.VasoTracker 2 provides free software and low‐cost hardware for vessel diameter analysis, broadening access to advanced vascular research tools. The platform's open‐source nature allows researchers to modify and extend the system for specific applications. This flexibility, combined with significant cost savings, benefits vascular researchers worldwide. image Key points: VasoTracker 2 is an open‐source platform that combines versatile vessel diameter tracking software with modular low‐cost hardware components for vascular physiology research. The software enables multipoint diameter analysis across brightfield, fluorescence and ultrasound imaging modalities. The hardware includes a confocal‐compatible vessel chamber and programmable pressure controller (VasoMoto) that can be assembled into a complete pressure myograph system. The open‐source approach provides researchers with accessible tools for advanced vascular physiology experiments.

Publication Details

Journal
Strathprints: The University of Strathclyde institutional repository (University of Strathclyde)
Published
2025-11-15
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VasoTracker 2 : open-source software and hardware for tracking blood vessel diameter and assessing vascular function

Strathprints: The University of Strathclyde institutional repository (University of Strathclyde)
Geochemistry and Geologic Mapping
article

VasoTracker 2 : open-source software and hardware for tracking blood vessel diameter and assessing vascular function

article en

Abstract

VasoTracker 2 is a collection of open‐source tools for blood vessel diameter measurement and vascular physiology research, featuring automated diameter tracking software and low‐cost myography hardware components. This blood vessel analysis platform addresses the need for accessible alternatives to expensive commercial vascular imaging systems by providing comprehensive tools for studying vessel reactivity and endothelial function. The software enables multipoint diameter tracking in branched vessels using advanced edge detection algorithms, supporting brightfield microscopy, fluorescence imaging and ultrasound recordings. Automated pressure protocols enable standardized myogenic tone experiments, and both real‐time and offline analysis of pre‐recorded data are supported. The platform's versatility allows researchers to study vascular dynamics across diverse experimental conditions, from isolated vessel preparations to in vivo imaging applications. For ex vivo applications, VasoTracker 2 includes modular, low‐cost open‐source pressure myograph hardware: a confocal‐compatible vessel chamber and a programmable pressure controller, VasoMoto. These components enable construction of a complete pressure myograph system at a significantly reduced cost compared to commercial alternatives. The hardware integrates seamlessly with the diameter measurement software.VasoTracker 2 provides free software and low‐cost hardware for vessel diameter analysis, broadening access to advanced vascular research tools. The platform's open‐source nature allows researchers to modify and extend the system for specific applications. This flexibility, combined with significant cost savings, benefits vascular researchers worldwide. image Key points: VasoTracker 2 is an open‐source platform that combines versatile vessel diameter tracking software with modular low‐cost hardware components for vascular physiology research. The software enables multipoint diameter analysis across brightfield, fluorescence and ultrasound imaging modalities. The hardware includes a confocal‐compatible vessel chamber and programmable pressure controller (VasoMoto) that can be assembled into a complete pressure myograph system. The open‐source approach provides researchers with accessible tools for advanced vascular physiology experiments.

Strathprints: The University of Strathclyde institutional repository (University of Strathclyde)
American Heart Association, University of Pennsylvania, Foundation for Cardiovascular Research, British Heart Foundation, Fondation Leducq, Anschutz Medical Campus, University of Colorado, National Institute on Aging, National Heart, Lung, and Blood Institute, National Institute of General Medical Sciences, National Institute of Diabetes and Digestive and Kidney Diseases, National Institute of Neurological Disorders and Stroke, National Center for Complementary and Integrative Health, Cardiovascular Research Institute of Vermont, Larner College of Medicine, University of Vermont
Openalex Percentile: Top 36%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.