Torque Preservation in DFIG Systems During Voltage Dips With Modulated Stator-Connected Dynamic Braking Resistor

This article proposes a novel approach to enhancing the low-voltage ride-through capability of doubly-fed induction generator wind turbines using a dynamically modulated braking resistor (DBR) connected in series with the stator windings. Unlike conventional DBR-based methods that focus primarily on mitigating electrical transients, the proposed approach emphasizes maintaining the generator’s electromagnetic torque at its prefault level during grid voltage dips. The DBR resistance is calculated in real time based on analytical expressions derived from the system’s model. By properly selecting the DBR resistance during the fault, the excess mechanical power that cannot be transferred to the grid is dissipated within the resistor, allowing the generator torque to remain constant during the fault, which helps maintain rotor speed and mitigate electrical transients. The proposed strategy is validated through both simulation and experimental results under symmetrical fault conditions, demonstrating superior torque stability, reduced current transients, and improved postfault recovery compared to fixed-resistance DBR schemes.

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2025-09-12
DOI
https://doi.org/10.1109/tpel.2025.3609526
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Torque Preservation in DFIG Systems During Voltage Dips With Modulated Stator-Connected Dynamic Braking Resistor

IEEE Transactions on Power Electronics
Geochemistry and Geologic Mapping
article

Torque Preservation in DFIG Systems During Voltage Dips With Modulated Stator-Connected Dynamic Braking Resistor

article en

Abstract

This article proposes a novel approach to enhancing the low-voltage ride-through capability of doubly-fed induction generator wind turbines using a dynamically modulated braking resistor (DBR) connected in series with the stator windings. Unlike conventional DBR-based methods that focus primarily on mitigating electrical transients, the proposed approach emphasizes maintaining the generator’s electromagnetic torque at its prefault level during grid voltage dips. The DBR resistance is calculated in real time based on analytical expressions derived from the system’s model. By properly selecting the DBR resistance during the fault, the excess mechanical power that cannot be transferred to the grid is dissipated within the resistor, allowing the generator torque to remain constant during the fault, which helps maintain rotor speed and mitigate electrical transients. The proposed strategy is validated through both simulation and experimental results under symmetrical fault conditions, demonstrating superior torque stability, reduced current transients, and improved postfault recovery compared to fixed-resistance DBR schemes.

IEEE Transactions on Power ElectronicsVol. 41(2)
Universidad Pública de Navarra (UPNA) (ES), Czech Technical University in Prague (CZ)
European Commission, European Regional Development Fund, Agencia Estatal de Investigación
Affordable and clean energy
Openalex Percentile: Top 37%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Torque Preservation in DFIG Systems During Voltage Dips With Modulated Stator-Connected Dynamic Braking Resistor · IEEE Transactions on Power Electronics (2025) | TGRS Research Map | TGRS