Measurement and Quantitative Analysis of Ozone Generation in Radiation Treatment Room Due to High-Energy Photon

Ozone generation in radiation treatment rooms poses a health risk due to high-energy photon interactions with air molecules. This study quantifies ozone concentration under varying conditions and assesses its impact on occupational exposure. Using a self-designed phantom, ozone measurements were taken under various conditions, including different photon energies (i.e., 6 and 15 MV), dose rates (i.e., 300 and 600 MU/min), and doses (i.e., 500 and 1,000 MU), with each condition measured ten times. Results showed that ozone concentration increased significantly with higher photon energy and dose, while the dose rate had a minimal effect, except at 15 MV. The highest ozone level (0.161 ± 0.003 ppm) exceeded FDA medical device limits and air quality standards. Ozone persisted for six minutes before normalizing, posing potential health risks to workers. These findings highlight the need for improved ventilation strategies in radiation treatment rooms.

Institutions

Publication Details

Journal
Indonesian Journal of Science and Technology
Published
2025-03-24
DOI
https://doi.org/10.17509/ijost.v10i2.82093
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement and Quantitative Analysis of Ozone Generation in Radiation Treatment Room Due to High-Energy Photon

Indonesian Journal of Science and Technology
Geochemistry and Geologic Mapping
article

Measurement and Quantitative Analysis of Ozone Generation in Radiation Treatment Room Due to High-Energy Photon

article en

Abstract

Ozone generation in radiation treatment rooms poses a health risk due to high-energy photon interactions with air molecules. This study quantifies ozone concentration under varying conditions and assesses its impact on occupational exposure. Using a self-designed phantom, ozone measurements were taken under various conditions, including different photon energies (i.e., 6 and 15 MV), dose rates (i.e., 300 and 600 MU/min), and doses (i.e., 500 and 1,000 MU), with each condition measured ten times. Results showed that ozone concentration increased significantly with higher photon energy and dose, while the dose rate had a minimal effect, except at 15 MV. The highest ozone level (0.161 ± 0.003 ppm) exceeded FDA medical device limits and air quality standards. Ozone persisted for six minutes before normalizing, posing potential health risks to workers. These findings highlight the need for improved ventilation strategies in radiation treatment rooms.

Indonesian Journal of Science and TechnologyVol. 10(2)
Jeonju University (KR)
Affordable and clean energy
Openalex Percentile: Top 38%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.