Optimized Secondary Arc Mitigation in Hybrid AC/DC Transmission Lines

Hybrid AC/DC transmission lines are an efficient alternative to conventional AC/AC systems. However, protection design poses unique challenges that motivate further study. The present paper introduces a genetic optimization framework targeting critical performance metrics: secondary arc current (SAC) suppression, secondary arc extinction time (SET) reduction, and transient recovery voltage (TRV) stabilization. Harnessing synchronized PSCAD-MATLAB simulations based on the Nondominated Sorting Genetic Algorithm II (NSGA-II), shunt reactor parameters are optimized for both baseline (AC/AC) and hybrid configurations. Optimized neutral reactors reduce unnecessary compensation by up to 85% compared to analytical designs that ignore inter-circuit coupling. Outperforming the conventional AC/AC system, the best-performing hybrid configuration requires 22% less reactor capacity and achieves up to a 96% size reduction relative to analytically derived parameters. These results demonstrate that single-phase auto-reclosing (SPAR) in hybrid lines can ensure both protection reliability and economic efficiency when supported by tuned shunt compensation.

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2025-09-12
DOI
https://doi.org/10.1109/tpwrd.2025.3608962
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized Secondary Arc Mitigation in Hybrid AC/DC Transmission Lines

IEEE Transactions on Power Delivery
Geochemistry and Geologic Mapping
article

Optimized Secondary Arc Mitigation in Hybrid AC/DC Transmission Lines

article en

Abstract

Hybrid AC/DC transmission lines are an efficient alternative to conventional AC/AC systems. However, protection design poses unique challenges that motivate further study. The present paper introduces a genetic optimization framework targeting critical performance metrics: secondary arc current (SAC) suppression, secondary arc extinction time (SET) reduction, and transient recovery voltage (TRV) stabilization. Harnessing synchronized PSCAD-MATLAB simulations based on the Nondominated Sorting Genetic Algorithm II (NSGA-II), shunt reactor parameters are optimized for both baseline (AC/AC) and hybrid configurations. Optimized neutral reactors reduce unnecessary compensation by up to 85% compared to analytical designs that ignore inter-circuit coupling. Outperforming the conventional AC/AC system, the best-performing hybrid configuration requires 22% less reactor capacity and achieves up to a 96% size reduction relative to analytically derived parameters. These results demonstrate that single-phase auto-reclosing (SPAR) in hybrid lines can ensure both protection reliability and economic efficiency when supported by tuned shunt compensation.

IEEE Transactions on Power DeliveryVol. 40(6)
North China Electric Power University (CN), Universidade Estadual de Campinas (UNICAMP) (BR)
Climate action
Openalex Percentile: Top 38%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimized Secondary Arc Mitigation in Hybrid AC/DC Transmission Lines · IEEE Transactions on Power Delivery (2025) | TGRS Research Map | TGRS