Utilizing A Bioclimatic Architectural Approach on The Roof To Optimize Building Thermal Performance. Case Study: Universitas Diponegoro Campus Mosque

Local wisdom enhances building aesthetics and imparts philosophical values. Bioclimatic architecture has become popular among architects and designers because it reduces energy consumption without harming the environment. A study at the Universitas Diponegoro Campus Mosque applied bioclimatic design using a traditional joglo roof model simulated with Autodesk Ecotect. Measurements showed the maximum suhue on the second floor reached 28°C. Simulations indicated that bioclimatic design could reduce indoor suhues by 4.3°C - 5.2°C to 24.5°C. This result shows a lower suhue difference compared to the existing design by 7.5°C. This design can be a prospective solution for improving thermal comfort and providing an environmentally friendly design.

Institutions

Publication Details

Journal
Jurnal Arsitektur dan Perencanaan (JUARA)
Published
2024-09-30
DOI
https://doi.org/10.31101/juara.v7i2.3669
Citations
1
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilizing A Bioclimatic Architectural Approach on The Roof To Optimize Building Thermal Performance. Case Study: Universitas Diponegoro Campus Mosque

1 citations
Jurnal Arsitektur dan Perencanaan (JUARA)
Geochemistry and Geologic Mapping
0.35
article

Utilizing A Bioclimatic Architectural Approach on The Roof To Optimize Building Thermal Performance. Case Study: Universitas Diponegoro Campus Mosque

article en
1 citations

Abstract

Local wisdom enhances building aesthetics and imparts philosophical values. Bioclimatic architecture has become popular among architects and designers because it reduces energy consumption without harming the environment. A study at the Universitas Diponegoro Campus Mosque applied bioclimatic design using a traditional joglo roof model simulated with Autodesk Ecotect. Measurements showed the maximum suhue on the second floor reached 28°C. Simulations indicated that bioclimatic design could reduce indoor suhues by 4.3°C - 5.2°C to 24.5°C. This result shows a lower suhue difference compared to the existing design by 7.5°C. This design can be a prospective solution for improving thermal comfort and providing an environmentally friendly design.

Jurnal Arsitektur dan Perencanaan (JUARA)Vol. 7(2)
Diponegoro University (ID), Universiti Brunei Darussalam (BN)
Affordable and clean energy
Openalex Percentile: Top 28%
Geochemistry and Geologic Mapping
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.