Predicting overloading plate failure using specimen-specific finite element models combined with implantable sensors.

Background Mechanical failure of plate osteosyntheses, such as plate bending, still occur in patients. While finite element (FE) models can simulate the mechanical behavior of a bone-plate construct, they lack in vivo validation due to unknown loads. The advent of implantable sensors, which monitor fracture healing by measuring plate deformation, presents an opportunity to validate these FE models in vivo. However, there is currently no established link between the sensor signal and the predicted implant failure. The aim of this study was to bridge this gap by combining FE simulations with sensor data to predict experimentally obtained implant failure of bone-plate constructs. Methods Seven cadaveric ovine tibia shaft fractures, fixed with locking plates, were tested for quasi-static failure, with implantable sensors monitoring plate bending deformation. These setups were mirrored in FE models, where virtual sensor signals, calibrated from a four-point bending test on the isolated sensor, were compared to experimental signals at the onset of plate bending. Results There was a high correlation between the experimental and virtual sensor signals from the four-point bending test (R2 > 0.99). The construct-specific FE models, with the calibrated virtual sensor signals, demonstrated a strong correlation with experimental sensor signals at yield (concordance correlation coefficient = 0.89, standard error of estimate = 187.0, relative standard error = 11.9 %). Conclusion FE models accurately predicted sensor signals at plate bending onset, enabling retrospective in vivo validation without load data and supporting tailored rehabilitation to lower patient complication rates.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-04-08
DOI
https://doi.org/10.48620/87783
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predicting overloading plate failure using specimen-specific finite element models combined with implantable sensors.

Open Access CRIS of the University of Bern
Geochemistry and Geologic Mapping
article

Predicting overloading plate failure using specimen-specific finite element models combined with implantable sensors.

article en

Abstract

Background Mechanical failure of plate osteosyntheses, such as plate bending, still occur in patients. While finite element (FE) models can simulate the mechanical behavior of a bone-plate construct, they lack in vivo validation due to unknown loads. The advent of implantable sensors, which monitor fracture healing by measuring plate deformation, presents an opportunity to validate these FE models in vivo. However, there is currently no established link between the sensor signal and the predicted implant failure. The aim of this study was to bridge this gap by combining FE simulations with sensor data to predict experimentally obtained implant failure of bone-plate constructs. Methods Seven cadaveric ovine tibia shaft fractures, fixed with locking plates, were tested for quasi-static failure, with implantable sensors monitoring plate bending deformation. These setups were mirrored in FE models, where virtual sensor signals, calibrated from a four-point bending test on the isolated sensor, were compared to experimental signals at the onset of plate bending. Results There was a high correlation between the experimental and virtual sensor signals from the four-point bending test (R2 > 0.99). The construct-specific FE models, with the calibrated virtual sensor signals, demonstrated a strong correlation with experimental sensor signals at yield (concordance correlation coefficient = 0.89, standard error of estimate = 187.0, relative standard error = 11.9 %). Conclusion FE models accurately predicted sensor signals at plate bending onset, enabling retrospective in vivo validation without load data and supporting tailored rehabilitation to lower patient complication rates.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 40%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Predicting overloading plate failure using specimen-specific finite element models combined with implantable sensors. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS