Sviluppo di un sistema di verifica della dose in vivo in radioterapia basato su Deep Learning e immagini EPID

Modern radiotherapy requires high precision in dose delivery to ensure tumor control and minimize damage to healthy tissue. In-vivo dose monitoring is crucial due to treatment complexity and potential errors. EPIDs (Electronic Portal Imaging Devices) offer real-time data and, recently, a Deep Learning model has been developed to convert EPID images into clinically relevant Portal Dose (PD) predictions. Trained on a large dataset of EPID images and dose distributions from the Monaco TPS, the model is evaluated in this thesis for two main goals: assessing its applicability in an in-vivo alert system and quantifying its sensitivity to treatment errors. The alert system aims to detect significant discrepancies between predicted and delivered doses in real-time. Validation involved EPID images of various phantoms (anthropomorphic, modular, solid water) with controlled variations in Monitor Units (MU), positioning, gantry angle, and added thickness. The model showed good sensitivity: GPR (3%, 3 mm) dropped below 95% for MU >102.4–109.3, positioning errors >3.9–4.6 mm, gantry deviations >8.9°, and added thicknesses of 1–3 mm. These results highlight the importance of evaluation metrics and guide optimization for clinical implementation. Further improvements to the model and phantom design were also identified.

Publication Details

Journal
Electronic Theses and Dissertations Repository (University of Pisa)
Published
2025-07-12
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sviluppo di un sistema di verifica della dose in vivo in radioterapia basato su Deep Learning e immagini EPID

Electronic Theses and Dissertations Repository (University of Pisa)
Geochemistry and Geologic Mapping
article

Sviluppo di un sistema di verifica della dose in vivo in radioterapia basato su Deep Learning e immagini EPID

article en

Abstract

Modern radiotherapy requires high precision in dose delivery to ensure tumor control and minimize damage to healthy tissue. In-vivo dose monitoring is crucial due to treatment complexity and potential errors. EPIDs (Electronic Portal Imaging Devices) offer real-time data and, recently, a Deep Learning model has been developed to convert EPID images into clinically relevant Portal Dose (PD) predictions. Trained on a large dataset of EPID images and dose distributions from the Monaco TPS, the model is evaluated in this thesis for two main goals: assessing its applicability in an in-vivo alert system and quantifying its sensitivity to treatment errors. The alert system aims to detect significant discrepancies between predicted and delivered doses in real-time. Validation involved EPID images of various phantoms (anthropomorphic, modular, solid water) with controlled variations in Monitor Units (MU), positioning, gantry angle, and added thickness. The model showed good sensitivity: GPR (3%, 3 mm) dropped below 95% for MU >102.4–109.3, positioning errors >3.9–4.6 mm, gantry deviations >8.9°, and added thicknesses of 1–3 mm. These results highlight the importance of evaluation metrics and guide optimization for clinical implementation. Further improvements to the model and phantom design were also identified.

Electronic Theses and Dissertations Repository (University of Pisa)
Good health and well-being
Openalex Percentile: Top 41%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.