Multiple Linear Model Analysis of Indoor Air Quality for Air Conditioning System in Office Building

The building performance is measured through the power consumption of the air conditioning system and indoor air quality (IAQ) of the building spaces to provide sufficient cooling while at the same time satisfying thermal comfort. The multiple linear model of Piecewise linear (PWL) and Multiple Linear Regression (MLR) model is used to accurately estimate the power consumption of the air conditioning system considering IAQ parameters such as carbon dioxide concentration, indoor air temperature, and humidity. The IAQ parameters are usually modelled individually for the building without proper correlation with the power consumption of the air conditioning system. This problem makes the modelling results unrealistic to the building performance solutions. This paper focuses on identifying the relationship between power consumption with integrated IAQ parameters of CO2 concentration, air temperature, and humidity for Air Conditioning Mechanical and Ventilation (ACMV) system in the office building. The results demonstrate the power consumption estimation model considering IAQ parameters for different time zones is accurate and acceptable with a percentage difference of less than 1 % from the real data. The power consumption estimation model can be used to predict future power consumption with optimum range values for IAQ parameters for sustainable utilisation of energy.

Institutions

Publication Details

Journal
TeesRep (Teesside University)
Published
2024-11-30
DOI
https://doi.org/10.3303/cet24113022
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiple Linear Model Analysis of Indoor Air Quality for Air Conditioning System in Office Building

TeesRep (Teesside University)
Geochemistry and Geologic Mapping
article

Multiple Linear Model Analysis of Indoor Air Quality for Air Conditioning System in Office Building

article en

Abstract

The building performance is measured through the power consumption of the air conditioning system and indoor air quality (IAQ) of the building spaces to provide sufficient cooling while at the same time satisfying thermal comfort. The multiple linear model of Piecewise linear (PWL) and Multiple Linear Regression (MLR) model is used to accurately estimate the power consumption of the air conditioning system considering IAQ parameters such as carbon dioxide concentration, indoor air temperature, and humidity. The IAQ parameters are usually modelled individually for the building without proper correlation with the power consumption of the air conditioning system. This problem makes the modelling results unrealistic to the building performance solutions. This paper focuses on identifying the relationship between power consumption with integrated IAQ parameters of CO2 concentration, air temperature, and humidity for Air Conditioning Mechanical and Ventilation (ACMV) system in the office building. The results demonstrate the power consumption estimation model considering IAQ parameters for different time zones is accurate and acceptable with a percentage difference of less than 1 % from the real data. The power consumption estimation model can be used to predict future power consumption with optimum range values for IAQ parameters for sustainable utilisation of energy.

TeesRep (Teesside University)
Technical University of Malaysia Malacca (MY), Teesside University (GB)
Openalex Percentile: Top 46%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.