Local diagnostic reference levels for lower limb angiography procedure in Morocco

The escalating utilization and complexity of fluoroscopically guided procedures contribute to prolonged examination durations and heightened risks of adverse radiation risk. Diagnostic Reference Levels (DRLs) are essential for optimizing radiation dose. The aim of this study is to establish local DRLs for Lower Limb Angiography (LLA) procedure. The investigation was conducted at at the Mohammed VI University Hospital Center in Marrakech, Morocco. The dosimetric data collected were the cumulative Dose Area Product (DAP), Fluoroscopic Time (FT), and Number of Frames (NF). The quantities' distributions were analyzed statistically, and local DRLs were determined as the 75th percentile, with the medians as typical values. The proposed LDRLs were compared to international studies. A total of 100 patients were included and performed examinations using a single C-arm machine. The Typical doses in terms of Kair were 0.21Gy, 59.34 Gy.cm2 for DAP, 1.1 min for FT and 538 frames. The derived local DRLs and Typical doses in terms of DAP, Kair, and NF were largely higher than those published by the other international studies. In terms of FT, the local DRL and typical value were significantly lower than values defined in other studies. These comparisons revealed a significant potential for optimization. This research establishes a standard for radiation dose in LLA examination at the studied hospital. These findings can inform future investigations in the country, facilitating comparative analyses.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-04-30
DOI
https://doi.org/10.5281/zenodo.17097137
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Local diagnostic reference levels for lower limb angiography procedure in Morocco

Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Geologic Mapping
article

Local diagnostic reference levels for lower limb angiography procedure in Morocco

article en

Abstract

The escalating utilization and complexity of fluoroscopically guided procedures contribute to prolonged examination durations and heightened risks of adverse radiation risk. Diagnostic Reference Levels (DRLs) are essential for optimizing radiation dose. The aim of this study is to establish local DRLs for Lower Limb Angiography (LLA) procedure. The investigation was conducted at at the Mohammed VI University Hospital Center in Marrakech, Morocco. The dosimetric data collected were the cumulative Dose Area Product (DAP), Fluoroscopic Time (FT), and Number of Frames (NF). The quantities' distributions were analyzed statistically, and local DRLs were determined as the 75th percentile, with the medians as typical values. The proposed LDRLs were compared to international studies. A total of 100 patients were included and performed examinations using a single C-arm machine. The Typical doses in terms of Kair were 0.21Gy, 59.34 Gy.cm2 for DAP, 1.1 min for FT and 538 frames. The derived local DRLs and Typical doses in terms of DAP, Kair, and NF were largely higher than those published by the other international studies. In terms of FT, the local DRL and typical value were significantly lower than values defined in other studies. These comparisons revealed a significant potential for optimization. This research establishes a standard for radiation dose in LLA examination at the studied hospital. These findings can inform future investigations in the country, facilitating comparative analyses.

Zenodo (CERN European Organization for Nuclear Research)
Cadi Ayyad University (MA), Université Hassan 1er (MA)
Partnerships for the goals
Openalex Percentile: Top 45%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Local diagnostic reference levels for lower limb angiography procedure in Morocco · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS