Estimation of cup orientation on intraoperative fluoroscopy in total hip arthroplasty: how safe is the safe zone-an experimental study.

Background Accurate acetabular cup orientation in total hip arthroplasty (THA) is crucial for successful outcomes. Intraoperative fluoroscopy may be used to evaluate acetabular cup placement. This study aimed to evaluate the accuracy of purely visual estimation of cup inclination and anteversion using intraoperative fluoroscopy, considering different surgeon experience levels and cup designs.Methods Thirty-five surgeons with varying levels of experience participated in the study. Standardized fluoroscopic images depicting two different cementless acetabular cup designs placed in a bone model were used. Inclination values ranged from 20 to 60°, while anteversion values ranged from 0 to 40°, both in 5° increments, resulting in 162 combinations of cup orientation. Each participant received a randomly compiled sequence of all images and was provided with instructions for estimating inclination and anteversion angles, and was asked additionally to categorize cup orientations into predefined safe zones, utilizing two definitions: (a) an institutional safe zone (inclination 35 to 45°, anteversion 10 to 20°), and (b) the safe zone according to Lewinnek et al. (inclination 30 to 50°, anteversion 5 to 25°). Participants had no time limit and were not allowed to use measuring tools during the estimation process.Results No significant difference in the precise estimation of inclination and anteversion was found among surgeons of varying experience levels. However, the ability to correctly identify whether cup orientation fell within predefined safe zones improved with surgical experience and seniority. Cup design influenced estimation of inclination, with one design showing superior accuracy. Estimation of anteversion remained consistent across designs. The influence of anteversion on inclination estimation and vice versa was minimal. Safe zone definitions did not significantly affect classification accuracy between cup designs.Conclusion While surgical experience did not improve angle estimation accuracy in degrees, it was associated with more accurate identifications of positions within clinically relevant safe zones. Cup design influenced inclination estimation. Our findings emphasize the importance of precise cup positioning in THA and highlight areas for potential improvement in surgical practice and training.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-09-08
DOI
https://doi.org/10.48620/91264
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimation of cup orientation on intraoperative fluoroscopy in total hip arthroplasty: how safe is the safe zone-an experimental study.

Open Access CRIS of the University of Bern
Geochemistry and Geologic Mapping
article

Estimation of cup orientation on intraoperative fluoroscopy in total hip arthroplasty: how safe is the safe zone-an experimental study.

article en

Abstract

Background Accurate acetabular cup orientation in total hip arthroplasty (THA) is crucial for successful outcomes. Intraoperative fluoroscopy may be used to evaluate acetabular cup placement. This study aimed to evaluate the accuracy of purely visual estimation of cup inclination and anteversion using intraoperative fluoroscopy, considering different surgeon experience levels and cup designs.Methods Thirty-five surgeons with varying levels of experience participated in the study. Standardized fluoroscopic images depicting two different cementless acetabular cup designs placed in a bone model were used. Inclination values ranged from 20 to 60°, while anteversion values ranged from 0 to 40°, both in 5° increments, resulting in 162 combinations of cup orientation. Each participant received a randomly compiled sequence of all images and was provided with instructions for estimating inclination and anteversion angles, and was asked additionally to categorize cup orientations into predefined safe zones, utilizing two definitions: (a) an institutional safe zone (inclination 35 to 45°, anteversion 10 to 20°), and (b) the safe zone according to Lewinnek et al. (inclination 30 to 50°, anteversion 5 to 25°). Participants had no time limit and were not allowed to use measuring tools during the estimation process.Results No significant difference in the precise estimation of inclination and anteversion was found among surgeons of varying experience levels. However, the ability to correctly identify whether cup orientation fell within predefined safe zones improved with surgical experience and seniority. Cup design influenced estimation of inclination, with one design showing superior accuracy. Estimation of anteversion remained consistent across designs. The influence of anteversion on inclination estimation and vice versa was minimal. Safe zone definitions did not significantly affect classification accuracy between cup designs.Conclusion While surgical experience did not improve angle estimation accuracy in degrees, it was associated with more accurate identifications of positions within clinically relevant safe zones. Cup design influenced inclination estimation. Our findings emphasize the importance of precise cup positioning in THA and highlight areas for potential improvement in surgical practice and training.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 47%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Estimation of cup orientation on intraoperative fluoroscopy in total hip arthroplasty: how safe is the safe zone-an experimental study. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS