Artificial Intelligence-Driven Automated Design of Anterior and Posterior Crowns Under Diverse Occlusal Scenarios.

Objective To evaluate the impact of occlusion type and artificial intelligence-based computer-aided design (CAD) software on the geometric accuracy and clinical quality of auto-generated anterior and posterior crown designs.Methods Five typodont models representing various occlusion types (normal, Class I anterior diastema, Class II division 1, Class II division 2, and Class III anterior crossbite occlusion) underwent crown preparation for the maxillary right central incisor and first molar. Ten sets of intraoral scans were obtained from each prepared model, and crown designs were automatically generated using two software programs: deep learning-based (DL; Dentbird) and conventional automated (CA; Auto Workflow, 3Shape) (n = 10). Surface deviations between the crown designs and preoperative tooth morphology were quantified using root mean square (RMS) values. Clinical crown quality was assessed using World Dental Federation (FDI) criteria. Scheirer-Ray-Hare and Fisher's exact tests were conducted (α = 0.05).Results Significant differences in surface deviation and clinical quality were observed between the various occlusion and software types. The DL group demonstrated higher RMS values than the CA group (p < 0.001). However, DL-generated crowns were of significantly better clinical quality (FDI scores) than CA-generated crowns, particularly for posterior teeth, in terms of marginal adaptation, proximal contacts, and anatomical form and contour (p < 0.05). The DL group demonstrated generally favorable outcomes when designing crowns for normal occlusion, but outcomes were less satisfactory when designing anterior crowns with diastemas.Conclusions Occlusal scenarios influenced the surface deviation and quality of auto-generated anterior and posterior crown designs. DL software produced higher-quality molar designs than CA software.Clinical Significance Automated crown design outcomes depend on occlusal scenarios and CAD software selection. DL-based CAD software demonstrated superior clinical quality, particularly for posterior crowns, indicating higher clinical suitability. However, further software refinement is needed to consistently produce clinically acceptable crowns under diverse occlusal conditions, such as anterior diastemas.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-09-08
DOI
https://doi.org/10.48620/91197
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial Intelligence-Driven Automated Design of Anterior and Posterior Crowns Under Diverse Occlusal Scenarios.

Open Access CRIS of the University of Bern
Geochemistry and Geologic Mapping
article

Artificial Intelligence-Driven Automated Design of Anterior and Posterior Crowns Under Diverse Occlusal Scenarios.

article en

Abstract

Objective To evaluate the impact of occlusion type and artificial intelligence-based computer-aided design (CAD) software on the geometric accuracy and clinical quality of auto-generated anterior and posterior crown designs.Methods Five typodont models representing various occlusion types (normal, Class I anterior diastema, Class II division 1, Class II division 2, and Class III anterior crossbite occlusion) underwent crown preparation for the maxillary right central incisor and first molar. Ten sets of intraoral scans were obtained from each prepared model, and crown designs were automatically generated using two software programs: deep learning-based (DL; Dentbird) and conventional automated (CA; Auto Workflow, 3Shape) (n = 10). Surface deviations between the crown designs and preoperative tooth morphology were quantified using root mean square (RMS) values. Clinical crown quality was assessed using World Dental Federation (FDI) criteria. Scheirer-Ray-Hare and Fisher's exact tests were conducted (α = 0.05).Results Significant differences in surface deviation and clinical quality were observed between the various occlusion and software types. The DL group demonstrated higher RMS values than the CA group (p < 0.001). However, DL-generated crowns were of significantly better clinical quality (FDI scores) than CA-generated crowns, particularly for posterior teeth, in terms of marginal adaptation, proximal contacts, and anatomical form and contour (p < 0.05). The DL group demonstrated generally favorable outcomes when designing crowns for normal occlusion, but outcomes were less satisfactory when designing anterior crowns with diastemas.Conclusions Occlusal scenarios influenced the surface deviation and quality of auto-generated anterior and posterior crown designs. DL software produced higher-quality molar designs than CA software.Clinical Significance Automated crown design outcomes depend on occlusal scenarios and CAD software selection. DL-based CAD software demonstrated superior clinical quality, particularly for posterior crowns, indicating higher clinical suitability. However, further software refinement is needed to consistently produce clinically acceptable crowns under diverse occlusal conditions, such as anterior diastemas.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 49%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.