Contactless pulse rate assessment

Remote photoplethysmography (rPPG) offers a promising solution for non-contact driver monitoring by detecting subtle blood flow-induced facial color changes from video. However, motion artifacts in dynamic driving environments remain key challenges. This study presents an rPPG framework that combines signal processing techniques before and after applying Eulerian Video Magnification (EVM) for pulse rate (PR) estimation in driving simulators. While not novel, the approach offers insights into the efficiency of the EVM method and its time complexity. We compare results of the proposed rPPG approach against reference Empatica E4 data and also compare it with existing achievements from the literature. Additionally, the possible bias of the Empatica E4 is further assessed using an independent dataset with both the Empatica E4 and the Faros 360 measurements. EVM slightly improves PR estimation, reducing the mean absolute error (MAE) from 6.48 bpm to 5.04 bpm (the lowest MAE (~2 bpm) was achieved under strict conditions) with an additional time required for EVM of about 20 s for 30 s sequence. Furthermore, statistically significant differences are identified between younger and older drivers in both reference and rPPG data. Our findings demonstrate the feasibility of using rPPG-based PR monitoring, encouraging further research in driving simulations.

Publication Details

Journal
Repository of the University of Ljubljana (University of Ljubljana)
Published
2025-09-04
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contactless pulse rate assessment

Repository of the University of Ljubljana (University of Ljubljana)
Geochemistry and Geologic Mapping
article

Contactless pulse rate assessment

article en

Abstract

Remote photoplethysmography (rPPG) offers a promising solution for non-contact driver monitoring by detecting subtle blood flow-induced facial color changes from video. However, motion artifacts in dynamic driving environments remain key challenges. This study presents an rPPG framework that combines signal processing techniques before and after applying Eulerian Video Magnification (EVM) for pulse rate (PR) estimation in driving simulators. While not novel, the approach offers insights into the efficiency of the EVM method and its time complexity. We compare results of the proposed rPPG approach against reference Empatica E4 data and also compare it with existing achievements from the literature. Additionally, the possible bias of the Empatica E4 is further assessed using an independent dataset with both the Empatica E4 and the Faros 360 measurements. EVM slightly improves PR estimation, reducing the mean absolute error (MAE) from 6.48 bpm to 5.04 bpm (the lowest MAE (~2 bpm) was achieved under strict conditions) with an additional time required for EVM of about 20 s for 30 s sequence. Furthermore, statistically significant differences are identified between younger and older drivers in both reference and rPPG data. Our findings demonstrate the feasibility of using rPPG-based PR monitoring, encouraging further research in driving simulations.

Repository of the University of Ljubljana (University of Ljubljana)
Openalex Percentile: Top 49%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.