COMPARING THE MECHANICAL PROPERTIES OF CONVENTIONAL, MILLED, AND 3D-PRINTED OCCLUSAL SPLINT MATERIALS: AN IN VITRO STUDY

Aim: Evidence on the mechanical properties of digitally manufactured occlusal splint materials remains scarce. The aim of this study was to evaluate and compare the mechanical properties of CAD/CAM fabricated occlusal splint materials versus conventionally heat-cured acrylic resin materials. Materials and Methods: A total of 100 specimens were manufactured for the present study. One CAD-CAM milled (ProArt CAD Splint), one heat-polymerized (SR IVOcap Clear), and three 3D-Printed (KeySplint Hard, NightGuard Firm2 and RoDIN Splint 2.0) resin materials were evaluated. Flexural strength, flexural modulus and surface hardness were measured. The three-point flexure test was used for the determination of flexural strength and modulus values, while Vickers hardness and Shore D hardness were measured to determine surface hardness. Twenty specimens (n = 20) of each material were tested using these procedures. Results were analyzed using analysis of variance (ANOVA) followed by Tukey’s post-hoc test. Results are presented as mean±SD and p-values less than 0.05 were considered statistically significant. Results: The values of flexural strength ranged from 9.8 ± 7.0 MPa to 121.0 ± 3.0 MPa. The values of flexural modulus ranged from 0.2 ± 0.2 GPa to 3.0 ± 0.2 GPa. The Vickers hardness values ranged from 10.1 ± 0.4 VHN to 22.9 ± 1.0 VHN, while the values of Shore D hardness ranged from 55.3 ± 0.5 HD to 95 ± 0 HD. Significant differences were found among the tested materials for flexural strength, flexural modulus and surface hardness (p < 0.0001). Conclusion: There are differences in the mechanical properties of the various tested occlusal splint materials. 3D-printed resins demonstrated adequate mechanical performance for occlusal splints when compared to conventional and milled PMMA, with the exception of surface hardness.

Publication Details

Journal
e-Publications@Marquette (Marquette University)
Published
2025-07-23
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMPARING THE MECHANICAL PROPERTIES OF CONVENTIONAL, MILLED, AND 3D-PRINTED OCCLUSAL SPLINT MATERIALS: AN IN VITRO STUDY

e-Publications@Marquette (Marquette University)
Geochemistry and Geologic Mapping
article

COMPARING THE MECHANICAL PROPERTIES OF CONVENTIONAL, MILLED, AND 3D-PRINTED OCCLUSAL SPLINT MATERIALS: AN IN VITRO STUDY

article en

Abstract

Aim: Evidence on the mechanical properties of digitally manufactured occlusal splint materials remains scarce. The aim of this study was to evaluate and compare the mechanical properties of CAD/CAM fabricated occlusal splint materials versus conventionally heat-cured acrylic resin materials. Materials and Methods: A total of 100 specimens were manufactured for the present study. One CAD-CAM milled (ProArt CAD Splint), one heat-polymerized (SR IVOcap Clear), and three 3D-Printed (KeySplint Hard, NightGuard Firm2 and RoDIN Splint 2.0) resin materials were evaluated. Flexural strength, flexural modulus and surface hardness were measured. The three-point flexure test was used for the determination of flexural strength and modulus values, while Vickers hardness and Shore D hardness were measured to determine surface hardness. Twenty specimens (n = 20) of each material were tested using these procedures. Results were analyzed using analysis of variance (ANOVA) followed by Tukey’s post-hoc test. Results are presented as mean±SD and p-values less than 0.05 were considered statistically significant. Results: The values of flexural strength ranged from 9.8 ± 7.0 MPa to 121.0 ± 3.0 MPa. The values of flexural modulus ranged from 0.2 ± 0.2 GPa to 3.0 ± 0.2 GPa. The Vickers hardness values ranged from 10.1 ± 0.4 VHN to 22.9 ± 1.0 VHN, while the values of Shore D hardness ranged from 55.3 ± 0.5 HD to 95 ± 0 HD. Significant differences were found among the tested materials for flexural strength, flexural modulus and surface hardness (p < 0.0001). Conclusion: There are differences in the mechanical properties of the various tested occlusal splint materials. 3D-printed resins demonstrated adequate mechanical performance for occlusal splints when compared to conventional and milled PMMA, with the exception of surface hardness.

e-Publications@Marquette (Marquette University)
Life below water
Openalex Percentile: Top 50%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

COMPARING THE MECHANICAL PROPERTIES OF CONVENTIONAL, MILLED, AND 3D-PRINTED OCCLUSAL SPLINT MATERIALS: AN IN VITRO STUDY · e-Publications@Marquette (Marquette University) (2025) | TGRS Research Map | TGRS