Development of a simple RP-HPLC method for the determination of EDTA residue in pharmaceutical clean-in-place (CIP) applications

A reversed-phase method was developed for the determination of EDTA (ethylenediaminetetraacetic acid) in a clean-in-place detergent through HPLC connected with UV or PDA detector. The EDTA signal was well above the detection limit and no interference was observed from water sample or any other swab and rinse diluent. The purpose of this study is to develop a simple, cost-effective reversed-phase HPLC method for the identification and quantification of EDTA in the cleaning solution. This method may contribute to further development and validation of residue detection from cleaning solutions used in pharmaceutical manufacturing. A HPLC system connected with UV detector and a column, Hamilton PRP-X100, 250 mm long x 4.1 mm internal diameter, 5 μm-thick was used to develop this method. This method is specific and precise for EDTA determination. The %RSD for six replicate injections was found to be within 10.0%. This method can be applied to cleaning validation samples and should be validated according to ICH guidelines before being used to analyze cleaning validation samples.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-03-30
DOI
https://doi.org/10.5281/zenodo.17059910
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a simple RP-HPLC method for the determination of EDTA residue in pharmaceutical clean-in-place (CIP) applications

Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Geologic Mapping
article

Development of a simple RP-HPLC method for the determination of EDTA residue in pharmaceutical clean-in-place (CIP) applications

article en

Abstract

A reversed-phase method was developed for the determination of EDTA (ethylenediaminetetraacetic acid) in a clean-in-place detergent through HPLC connected with UV or PDA detector. The EDTA signal was well above the detection limit and no interference was observed from water sample or any other swab and rinse diluent. The purpose of this study is to develop a simple, cost-effective reversed-phase HPLC method for the identification and quantification of EDTA in the cleaning solution. This method may contribute to further development and validation of residue detection from cleaning solutions used in pharmaceutical manufacturing. A HPLC system connected with UV detector and a column, Hamilton PRP-X100, 250 mm long x 4.1 mm internal diameter, 5 μm-thick was used to develop this method. This method is specific and precise for EDTA determination. The %RSD for six replicate injections was found to be within 10.0%. This method can be applied to cleaning validation samples and should be validated according to ICH guidelines before being used to analyze cleaning validation samples.

Zenodo (CERN European Organization for Nuclear Research)
University of Development Alternative (BD), University of Science and Technology Chittagong (BD)
Industry, innovation and infrastructure
Openalex Percentile: Top 52%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.