Comparative Harmonic Distortion Assessment in Distribution Networks with Distributed Generation: Analysis Under Steady-State and Dynamic Operating Conditions

The increasing penetration of distributed generation (DG) in modern distribution networks has improved reliability and efficiency but introduced new challenges to power quality. One of the most critical concerns is the presence of harmonics generated by nonlinear loads and inverter-based DGs. This paper investigates harmonic behavior in hybrid distribution networks under both normal and varying operating conditions. Simulation studies are conducted in MATLAB/Simulink on a photovoltaic–wind integrated distribution system. The study highlights the limitations of traditional harmonic detection methods, particularly in distinguishing between power quality disturbances and unintentional islanding events. A wavelet transform–artificial neural network (WT–ANN) framework is proposed for robust detection and classification. Results indicate that the proposed method provides enhanced accuracy and reliability in harmonic identification compared with conventional techniques. The findings suggest that advanced datadriven models can significantly improve grid stability and monitoring in DG-integrated systems.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-09-03
DOI
https://doi.org/10.5281/zenodo.17046922
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Harmonic Distortion Assessment in Distribution Networks with Distributed Generation: Analysis Under Steady-State and Dynamic Operating Conditions

Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Geologic Mapping
article

Comparative Harmonic Distortion Assessment in Distribution Networks with Distributed Generation: Analysis Under Steady-State and Dynamic Operating Conditions

article en

Abstract

The increasing penetration of distributed generation (DG) in modern distribution networks has improved reliability and efficiency but introduced new challenges to power quality. One of the most critical concerns is the presence of harmonics generated by nonlinear loads and inverter-based DGs. This paper investigates harmonic behavior in hybrid distribution networks under both normal and varying operating conditions. Simulation studies are conducted in MATLAB/Simulink on a photovoltaic–wind integrated distribution system. The study highlights the limitations of traditional harmonic detection methods, particularly in distinguishing between power quality disturbances and unintentional islanding events. A wavelet transform–artificial neural network (WT–ANN) framework is proposed for robust detection and classification. Results indicate that the proposed method provides enhanced accuracy and reliability in harmonic identification compared with conventional techniques. The findings suggest that advanced datadriven models can significantly improve grid stability and monitoring in DG-integrated systems.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 55%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.