Experimental and micro-finite element analysis of the toggling behaviour of a carbon fibre-reinforced PEEK pedicle screw.

Primary stability of pedicle screws is critical for successful spinal fixation, particularly in osteoporotic patients, where screw loosening occurs in over 50 % of cases. This study combined experimental and numerical approaches to evaluate the primary stability of carbon fibre-reinforced polyether-ether-ketone (CF/PEEK) screws under toggling loading conditions. Fifteen human cadaveric vertebrae with low bone mineral density were tested using a multidirectional loading setup with custom-designed, 3D-printed guides for accurate screw placement. Toggling tests were conducted under displacement-controlled linear loading-unloading ramps with increasing displacements (1, 2, and 4 mm). To complement the experiments, a sample-specific, explicit non-linear micro-finite element (μFE) model was developed to simulate the toggling tests. Experimental and numerical peak forces and tangential stiffnesses were compared at different displacement levels. Experimentally, no significant correlation was found between mean bone volume fraction in the vicinity of the screw and peak forces. Similarly, volumetric bone mineral density did not show significant correlation with the experimental biomechanical variables. However, μFE-derived peak forces showed significant correlation with experimental measurements at all displacement levels (R2 = 0.67, R2 = 0.60, R2 = 0.59 at 1 mm, 2 mm and 4 mm displacement, respectively), with the model slightly overestimating the experimental values at higher displacements (e.g., 4 mm). Across all data points, μFE and experimental peak forces strongly correlated (R2 = 0.92), following a power-law relationship. This study demonstrates that non-linear μFE models can reliably predict the primary stability of pedicle screws, offering potential for optimizing screw designs and reducing clinical failure rates associated with loosening.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-08-14
DOI
https://doi.org/10.48620/90925
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and micro-finite element analysis of the toggling behaviour of a carbon fibre-reinforced PEEK pedicle screw.

Open Access CRIS of the University of Bern
Geochemistry and Geologic Mapping
article

Experimental and micro-finite element analysis of the toggling behaviour of a carbon fibre-reinforced PEEK pedicle screw.

article en

Abstract

Primary stability of pedicle screws is critical for successful spinal fixation, particularly in osteoporotic patients, where screw loosening occurs in over 50 % of cases. This study combined experimental and numerical approaches to evaluate the primary stability of carbon fibre-reinforced polyether-ether-ketone (CF/PEEK) screws under toggling loading conditions. Fifteen human cadaveric vertebrae with low bone mineral density were tested using a multidirectional loading setup with custom-designed, 3D-printed guides for accurate screw placement. Toggling tests were conducted under displacement-controlled linear loading-unloading ramps with increasing displacements (1, 2, and 4 mm). To complement the experiments, a sample-specific, explicit non-linear micro-finite element (μFE) model was developed to simulate the toggling tests. Experimental and numerical peak forces and tangential stiffnesses were compared at different displacement levels. Experimentally, no significant correlation was found between mean bone volume fraction in the vicinity of the screw and peak forces. Similarly, volumetric bone mineral density did not show significant correlation with the experimental biomechanical variables. However, μFE-derived peak forces showed significant correlation with experimental measurements at all displacement levels (R2 = 0.67, R2 = 0.60, R2 = 0.59 at 1 mm, 2 mm and 4 mm displacement, respectively), with the model slightly overestimating the experimental values at higher displacements (e.g., 4 mm). Across all data points, μFE and experimental peak forces strongly correlated (R2 = 0.92), following a power-law relationship. This study demonstrates that non-linear μFE models can reliably predict the primary stability of pedicle screws, offering potential for optimizing screw designs and reducing clinical failure rates associated with loosening.

Open Access CRIS of the University of Bern
Biomechanics Institute of Valencia (ES)
Openalex Percentile: Top 61%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental and micro-finite element analysis of the toggling behaviour of a carbon fibre-reinforced PEEK pedicle screw. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS