D6.2 Results from functional and quality acceptance tests

We took measurements on a MiniStor prototype without photovoltaic thermal panels for winter and summer operating modes. These measurements included assessing several thermal parameters, evaluating the heat storage capacity, and analysing the pressure conditions within the system for each mode. Efficiency values werecalculated from the measured data. To carry out our measurements, we have set up at EMI’s facilities a specially designed mechanical device to simulate different thermal input and output conditions through usage of hot water at different temperature levels instead of that produced by the panels, which depends on weather conditions. The deliverable describes the procedures and equipment used, and the results obtained from these measurements. Measurements were not continuous in some cases due to faults which are typical during the prototype stage. Results from the measurements will be used in WP3 and for the product audit program (PAP).

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-02-07
DOI
https://doi.org/10.5281/zenodo.16979557
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

D6.2 Results from functional and quality acceptance tests

Zenodo (CERN European Organization for Nuclear Research)
Geochemistry and Geologic Mapping
article

D6.2 Results from functional and quality acceptance tests

article en

Abstract

We took measurements on a MiniStor prototype without photovoltaic thermal panels for winter and summer operating modes. These measurements included assessing several thermal parameters, evaluating the heat storage capacity, and analysing the pressure conditions within the system for each mode. Efficiency values werecalculated from the measured data. To carry out our measurements, we have set up at EMI’s facilities a specially designed mechanical device to simulate different thermal input and output conditions through usage of hot water at different temperature levels instead of that produced by the panels, which depends on weather conditions. The deliverable describes the procedures and equipment used, and the results obtained from these measurements. Measurements were not continuous in some cases due to faults which are typical during the prototype stage. Results from the measurements will be used in WP3 and for the product audit program (PAP).

Zenodo (CERN European Organization for Nuclear Research)
EMI Construction Quality Control (Hungary) (HU)
Affordable and clean energy
Openalex Percentile: Top 61%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

D6.2 Results from functional and quality acceptance tests · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS